	System Healthcheck for HP OpenVMS - Release Notes

Copyright 2001, 2004 Hewlett-Packard Development Company, L.P.

SHC V2.3-279 (March 2004)

* Changes from V2.2-229 to V2.3-279

  Updated SAN Command Script version to build 76. Note that if a system is
  running OpenVMS Alpha V7.3-2 and has HSZ or HSG controllers, ECO 
  VMS732_FIBRE_SCSI-V0100 should be applied. That patch fixes a known OpenVMS bug 
  which can cause the SAN Command Scripter to hang the system.

  Changed Security rules so that they fire on the customer's system. The SYSUAF 
  listing is no longer sent to HP. This is for security reasons and also because 
  some SYSUAF listings are extremely large. SYSUAF account listings are now saved
  to rule specific files in SHC$DATA e.g. SS008_'NODE'.LIS. The file name is 
  included as part of the rule evidence in the SHC Professional Report.

  The graphing utility, CSVPNG_ALPHA.EXE, is now included. This tool can be used
  to generate PNG charts from the T4 CSV data. See SHC$ROOT:[T4]CSVPNG.TXT for 
  more information.

  The SAN Command Scripter utility has been updated from V1.0A to V1.0B

  Several bugs have been fixed.

  A number of new rules have been added.


* bugfixes to V2.2-225 and V2.2-220
  
  PTR 36-1-3740  SHC VMS: SHC continuously resubmits if 'next-time' is in the past 
  PTR 36-1-3732  Regular schedule problem 

* some bugfixes to V2.2-218

SHC V2.2-218 (March 2003)

* Worldwire transport can now be used for SHC Data. Use 'D' for Transport Option.
* Installation will grant SHC$USER rights to installation username UAF record
  and adds this identifier to SHC directories and files.
* New and Revised TCPIP rules
* Collect data for HSZ\HSG\HSJ controllers and new Storage rules
* Added option to run T4 Performance Monitoring collection on Alpha V7.2-1 
  and later. See SYS$T4:README.TXT for more details.
* New performance rules based on T4 data. 
* User can control which T4 charts are generated by copying
  SHC$DIR:T4_METRICS.LIS to SHC$DATA and editing as required.
* Change collection file type to .SHC
* Further validation of configuration parameters
* Gather galaxy and partition id information
* Parse system logical names to locate system files
* Resolve more system logical names to disk device names
* Fix minor gather file logging error
* Updated copyright notice

SHC v2.1-129 (August 2002)

* Correct defensive programming code to avoid warnings and error messages.

SHC v2.1-114 (June 2002)

* add expiry date to SHC collector
* enhanced validation of SHC$DEFAULT.cfg data
* support for HP email addresses
* New Rules :
  SS075,FU507
* Revived Rules :
  LP069
* Rules Modified :
  LN080,LN081,LN082,LN083,LN084,LN085,LN086,LN087
  LN088,LN089,LP091,PF022,PF028,PF029,PF030,PF031
  PF032,PF049,PF500,PF502,SO001,SS007,SS049,SS060
  SS061,SS062,SS063,SS064,SS065,SS066,SS067,SS068
  SS069,SU005,SU006,SU007,SU015,SU020,VI003,VI005
  VI006,VI008,DI036,DI039,DI040,DI043,FU001,LN043
  LP042,LP062,LP064,LQ505,LQ508,LQ509,PC073,PF004
  PF006,PF010,PF024,PF504,FU500,IP521,UC521,FU501
  FU502,FU503,FU504,FU505,FU506
* Rules Reviewed and not changed :
  DI011,DI027,DI032,DI041,DI044,IP500,IP501,IP502
  IP510,IP511,IP512,IP523,LP007,LP027,LP043,LP065
  LP101,PC001,PC002,PC074,PF026,SS004,SS005,SS008
  SS009,SS010,SS013,SS014,SS015,SS016,SS017,SU002
  SU004,SU010,SU011,SU021,UC500,UC501,UC502,UC504
  UC508,UC510,UC511,UC512
* Disabled Rules :
  CO009,CO061,DA007,DA013,DA017,DI015,DI027,DI030,
  DI041,LD002,LN089,LP006,LP010,LP012,LP018,LP026
  LP035,LP036,LP039,LP044,LP046,LP056,LQ005,LQ006
  PC001,PC002,PC022,PC023,PC024,PC025,PC055,PC056
  PC057,PC058,PC060,PC061,PC066,PC067,PC068,PC069
  PC070,PD002,PD003,PD005,PD006,PD007,PD008,PD010
  PD011,PD013,PD014,PD016,PD017,PD019,PD020,PD029
  PD030,PF031,PF032,PF049,PF500,PH001,PH005,PH009
  PH010,PH011,PH012,PH013,PH014,PH015,PH016,PH017 
  PH018,PH020,PH021,PH040,PH041,PH042,PH043,PN021
  PN022,SO001,SS005,SS006,SS008,SS012,SS015,SS018
  SU001,SU005,SU022,SU023,SU024,SU025,SU026,SU027


SHC v2.1-80 (March 2002)
* FTP now available as a transport mechanism to fwd data from Customer sites to Compaq.
* SHC Collections can now be scheduled as weekly and Monthly
* PCSI Kit install Procedure
* The following s ( Bugs) have been resolved:
  - 13 critical
  - 31 high
  - 48 medium
  - 5 low
  - Total: 97
* New Rules :
  IP500,IP501,IP502,IP504,IP506,IP507,IP510,IP511
  IP512,IP513,IP521,IP522,IP523,IP524,DI043
* Rules Reviewed and Modified or Unchanged :
  DI009,DI017,DI020,DI027,DI028,DI032,LP004,LP011
  LP014,LP015,LP016,LP027,LP028,LP032,LP034,LP038
  LP041,LP042,LP043,LP047,LP049,LP058,LP059,LQ502
  LQ504,PC004,DA003,DA004,DA022,DN009,DN503,DN504
  DN512,DN514,DN518,DN519,DN520,LD011,UC520,UC522
  UC523,UC524,SS034,SS019,LP101,DN517,DI038,DI041
  DI042,DN505,DN510,LN006,LN020,LN091,LN093,LP007
  PF029,PF505,PF506,UC500,UC501,UC502,UC503,UC504
  UC505,UC506,UC507,UC508,UC509,UC510,UC511,UC512
  UC513,UC514,UC515,UC516,UC517,UC518,UC519,UC521
  FU004,LD007,LN080,LN081,LN082,LN083,LN084,LN085
  LN086,LN087,LN088,LN089,LQ505,PF002,PF017,PF019
  PF021,PF022,PF028,PF030,PF031,PF032,PF049,PF500
  PF502,PF503,VI003,VI005,VI006,VI008
* Disabled Rules :
  DI005,DI011,DI014,DI016,DI022,DI026,DI030,LP035
  PC001,PC002,SU010,FU002,LD010,LP010