! DS3 ATM Permanent Circuit - Example NCL script ! ============================================== ! ! +++++++++++++++++++++++++++++++++++++++++++++++++++ ! COPYRIGHT (C) 1995 BY DIGITAL EQUIPMENT CORPORATION, MAYNARD, ! MASSACHUSETTS. ! ALL RIGHTS RESERVED. ! ! THIS SOFTWARE IS FURNISHED UNDER A LICENSE AND MAY BE USED AND COPIED ! ONLY IN ACCORDANCE WITH THE TERMS OF SUCH LICENSE AND WITH THE ! INCLUSION OF THE ABOVE COPYRIGHT NOTICE. THIS SOFTWARE OR ANY OTHER ! COPIES THEREOF MAY NOT BE PROVIDED OR OTHERWISE MADE AVAILABLE TO ANY ! OTHER PERSON. NO TITLE TO AND OWNERSHIP OF THE SOFTWARE IS HEREBY ! TRANSFERRED. ! ! THE INFORMATION IN THIS SOFTWARE IS SUBJECT TO CHANGE WITHOUT NOTICE ! AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL EQUIPMENT ! CORPORATION. ! ! DIGITAL ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS ! SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY DIGITAL. ! +++++++++++++++++++++++++++++++++++++++++++++++++++ ! ! This script sets up the DECNIS to provide DS3 ATM Permanent circuits. ! ! Wherever appears, you should replace it with a value that matches ! your basic DECNIS configuration. ! ! This script is divided into three sections: ! EXTRA_CREATE.NCL ! EXTRA_SET.NCL ! EXTRA_ENABLE.NCL ! Each section should be added to the relevant user NCL script file for your ! DECNIS. For more information about user NCL script files, refer to the ! DECNIS Management manual. !=============================================================================== ! EXTRA_CREATE.NCL ! ++++++++++++++++ ! Add this section to NIS__EXTRA_CREATE.NCL file for your DECNIS. ! ! Ensure that a device exists for the network interface card. ! Create Device Unit W631-7 Name W631-7 ! ! Ensure that the multiplexed interface module exists. ! Create Multiplexed Interface ! ! Ensure that the ATM connection management module exists. ! Create ATM Connection Management ! ! Ensure that the ATM multiprotocol encapsulation module exists. ! Create ATM Multiprotocol Encapsulation ! ! Create the multiplexed interface line characteristics. Note that this ! example creates a DS3 interface type. ! Create Multiplexed Interface Line W631-7-0 - Communications Port = W631-7-0, - Interface Type = DS3, - Framing Type = DS3-CBitParity ! ! Create the multiplexed interface line logical channel and logical channel map. ! Create Multiplexed Interface Line W631-7-0 Logical Channel W631-7-0 Map {0} ! ! Create the ATM connection management line. ! Create ATM Connection Management Line W631-7-0 ! ! Create the ATM Connection Management PVCs. Note that there can be multiple ! PVCs on each ATM Connection Management line. The VCI valid range is 32 ! through 1023. The VPI valid range is 0 through 255 with 0 as the default. ! Specify that the ATM Adaptation Layer is of type AAL5 and that the ATM line ! uses LLC encapsulation. ! Create ATM Connection Management Line W631-7-0 PVC W631-7-0 - Virtual Circuit Identifier = 32, - Virtual Path Identifier = 0, - AAL Type = AAL5, - Encapsulation Type = LLC Encapsulation Create ATM Connection Management Line W631-7-0 PVC W631-7-1 - Virtual Circuit Identifier = 33, - Virtual Path Identifier = 0, - AAL Type = AAL5, - Encapsulation Type = LLC Encapsulation ! ! Create the ATM multiprotocol encapsulation links. ! Create ATM Multiprotocol Encapsulation Link W631-7-0 Create ATM Multiprotocol Encapsulation Link W631-7-1 ! ! Create the routing circuits. ! Create Routing Circuit W631-7-0 Type = ATM Permanent Create Routing Circuit W631-7-1 Type = ATM Permanent ! ! Create the bridge ports. ! Create Bridge Create Bridge Port PORT-8 Port Number = 8, Type = Remote Create Bridge Port PORT-9 Port Number = 9, Type = Remote ! ! If RIP has not already been configured on the DECNIS then create the RIP ! Routing Control Protocol entity. ! Create Routing Control Protocol RIP-1 Type = IP RIP ! !=============================================================================== ! EXTRA_SET.NCL ! ++++++++++++++++ ! Add this section to NIS__EXTRA_SET.NCL file for your DECNIS. ! ! Set the clock timing source to network or local. ! Set Multiplexed Interface Line W631-7-0 Clock Source = Local ! ! Set the line length. ! Set Multiplexed Interface Line W631-7-0 Line Length = 125 ! ! Associate the ATM connection management line with the multiplexed interface ! logical channel. ! Set ATM Connection Management Line W631-7-0 Lower Layer Entity = - Multiplexed Interface Line W631-7-0 Logical Channel W631-7-0 ! ! Disable PLCP and cell scrambling. ! Set ATM Connection Management Line W631-7-0 - PLCP = Disabled, - Cell Scrambling = Disabled ! ! Configure the circuits to suit the requirements of the routing circuit ! bandwidth and switch. ! Set ATM Connection Management Line W631-7-0 PVC W631-7-0 - Peak Rate = 100, - Minimum Guaranteed Rate = 60, - Traffic Shaping Priority = 1 Set ATM Connection Management Line W631-7-0 PVC W631-7-1 - Peak Rate = 100, - Minimum Guaranteed Rate = 40, - Traffic Shaping Priority = 1 ! ! Associate the ATM multiprotocol encapsulation links with the ATM connection ! management PVCs. ! Set ATM Multiprotocol Encapsulation Link W631-7-0 Lower Layer Entity = - ATM Connection Management Line W631-7-0 PVC W631-7-0 Set ATM Multiprotocol Encapsulation Link W631-7-1 Lower Layer Entity = - ATM Connection Management Line W631-7-0 PVC W631-7-1 ! ! Set the maximum protocol data unit (PDU) size of the ATM multiprotocol ! encapsulation links. ! Set ATM Multiprotocol Encapsulation Link W631-7-0 Maximum PDU Size = 4490 Set ATM Multiprotocol Encapsulation Link W631-7-1 Maximum PDU Size = 4490 ! ! Associate the routing circuit with the ATM multiprotocol encapsulation link. ! Set Routing Circuit W631-7-0 Data Link Entity = - ATM Multiprotocol Encapsulation Link W631-7-0 Set Routing Circuit W631-7-1 Data Link Entity = - ATM Multiprotocol Encapsulation Link W631-7-1 ! ! Set up the routing circuit network protocols and SDU size. ! Set Routing Circuit W631-7-0 Network Protocols = {IP,ISO8473}, - Manual Data Link SDU Size = 4490, - Manual IP Data Link SDU Size = 4490 Set Routing Circuit W631-7-1 Network Protocols = {IP}, - Manual Data Link SDU Size = 4490, - Manual IP Data Link SDU Size = 4490 ! ! Set the IP address and subnetwork mask for the IP interface. ! Set Routing Circuit W631-7-0 Subnet Address = - {Address = 1.1.1.0, Mask = 255.255.255.0} Set Routing Circuit W631-7-1 Subnet Address = - {Address = 4.4.4.5, Mask = 255.255.255.252} ! ! Set up bridging. ! Set Bridge Port PORT-8 Data Link Entity = - ATM Multiprotocol Encapsulation Link W631-7-0, - Port Cost = 10, - MAC Types = {FDDI}, - Manual Data Link SDU Size = 4500 Set Bridge Port PORT-8 Spanning Tree Enable = TRUE Set Bridge Port PORT-9 Data Link Entity = - ATM Multiprotocol Encapsulation Link W631-7-1, - Port Cost = 10, - MAC Types = {FDDI}, - Manual Data Link SDU Size = 4500 Set Bridge Port PORT-9 Spanning Tree Enable TRUE ! ! Set up the RIP Routing Control Protocol. ! Add Routing Control Protocol RIP-1 - IP Subnet = { {Address = 1.1.1.0, Mask = 255.255.255.0}, - {Address = 4.4.4.4, Mask = 255.255.255.252}} ! !=============================================================================== ! EXTRA_ENABLE.NCL ! ++++++++++++++++ ! Add this section to NIS__EXTRA_ENABLE.NCL file for your DECNIS. ! ! Set Device Unit W631-7 Auto Load False Enable Device Unit W631-7 Load Device Unit W631-7 Set Device Unit W631-7 Auto Load True ! Enable Multiplexed Interface Line W631-7-0 Logical Channel W631-7-0 Enable Multiplexed Interface Line W631-7-0 Enable ATM Connection Management Line W631-7-0 Enable ATM Multiprotocol Encapsulation Link W631-7-0 Enable ATM Multiprotocol Encapsulation Link W631-7-1 Enable Routing Circuit W631-7-0 Enable Routing Circuit W631-7-1 Enable Bridge Enable Bridge Port PORT-8 Enable Bridge Port PORT-9 ! ! If RIP has not already been configured on the DECNIS then enable the RIP ! Routing Control Protocol entity. ! Enable Routing Control Protocol RIP-1 ! !===============================================================================