VAXft System Services Reference Manual

*HyperReader

  CONTENTS

  Title Page

  Copyright Page

  Preface

  Part I    Reference Information

  1      All VAXft Systems

  1.1     DCL Commands for VAXft System Services

  SHOW ZONE

  START/ZONE

  STOP/ZONE

  1.2     Failover Set Manager (FSM) Utility

  ADD

  EXIT

  HELP

  REMOVE

  SET

  SHOW ADAPTERS

  2      VAXft Model 110, 410, 610, and 612 Systems

  2.1     FTSS$CONTROL Utility

  CALL

  EXIT

  HELP

  SET DEVICE

  SET EVENT

  SHOW DEVICE

  SHOW EVENTS

  2.2     Power and Cooling Monitor (PCM) QIO Interface

  SEND STATUS

  3      VAXft Model 810 Systems

  3.1     Power System Controller (PSC) QIO Interface

  GET STATUS

  GET VERSION

  3.2     External Event Notification Interface (ENI)
    3.2.1      FTSS$SERVER and the User Mailbox Interface
      3.2.1.1      The FTSS$ENIMBX Mailbox
      3.2.1.2      User Mailbox
    3.2.2      Registering With ENI
    3.2.3      Requesting Current System Configuration
    3.2.4      Enabling and Disabling Event Classes
    3.2.5      Stopping Event Notification
    3.2.6      ENI Status Response Message
    3.2.7      ENI Request System Configuration Response Message
    3.2.8      ENI System Configuration Event Message
    3.2.9      ENI System Error Event Message
    3.2.10     ENI Environmental Event Message
    3.2.11     ENI Symbols

  3.3     EXE$GL_FT_FLAGS Longword Definition

  Part II    Error Messages

  4      Introduction to Error Messages

  4.1     Format of System Messages

  4.2     Messages Without Identifications

  5      VAXft System Services Error Messages

  6      VMB Messages

  EXAMPLES

  2-1        Using the $ASSIGN System Service with PCM

  3-1        Using the $ASSIGN System Service with PSC

  FIGURES

  2-1        IOSB Return Contents for SEND STATUS

  2-2        PCIM Status Longword Format

  3-1        IOSB Return Contents for GET STATUS

  3-2        IOSB Return Contents for GET VERSION

  3-3        ENI Mailbox Interface

  3-4        Fault-Tolerant Flags Longword Format

  TABLES

  1-1        Physical Ethernet Adapter States

  2-1        Automatic Dialout Notification Events List

  2-2        Cabinet Identification Numbers

  2-3        SEND STATUS Device Dependent Parameters

  2-4        PCIM Status Longword Bit Descriptions

  2-5        VAXft Model 410, 610, and 612 Cabinet Temperature Zones

  3-1        GET STATUS Device Dependent Parameters

  3-2        PSC Status Longword Bit Descriptions

  3-3        VAXft Model 810 Cabinet Temperature Zones

  3-4        GET VERSION Device Dependent Parameters

  3-5        FTSS$ENIMBX Packet Fields

  3-6        REQ_FLAGS_WORD Bit Definitions

  3-7        User Mailbox Packet Fields

  3-8        REQCONFIG Message EVENT_DATA Fields

  3-9        Slot Configuration Longword Fields

  3-10       SYSCONFIG EVENT_CODE Values

  3-11       SYSCONFIG Message EVENT_DATA Fields

  3-12       SYS_MOD_INFO Fields

  3-13       ERROR EVENT_CODE Values

  3-14       ERROR Message EVENT_DATA Fields

  3-15       ERR_MOD_INFO Field Definitions

  3-17       ENVIR EVENT_CODE Values

  3-18       ENVIR Message EVENT_DATA Fields

  3-19       Referencing ENI Symbols

  3-20       EXE$GL_FT_FLAGS Longword Fields