     PRODUCT NAME:  DEC VUIT[TM] (Visual User Interface Tool),    SSA
     32.09.00-A
                    Version 1.0 for VMS Systems

     HARDWARE REQUIREMENTS

     Processors Supported

     VAX:      VAX 4000 Model 300

               VAX 6000 Model 200 Series,
               VAX 6000 Model 300 Series,
               VAX 6000 Model 400 Series,
               VAX 6000 Model 500 Series

               VAX 8200, VAX 8250, VAX 8300, VAX 8350,
               VAX 8500, VAX 8530, VAX 8550, VAX 8600,
               VAX 8650, VAX 8700, VAX 8800, VAX 8810,
               VAX 8820, VAX 8830, VAX 8840

               VAX 9000-210, VAX 9000-410

               VAXft 3000-310

               VAX-11/730, VAX-11/750, VAX-11/780, VAX-11/785

     MicroVAX: MicroVAX II, MicroVAX 2000,
               MicroVAX 3100, MicroVAX 3300,
               MicroVAX 3400, MicroVAX 3500,
               MicroVAX 3600, MicroVAX 3800,


                                  DIGITAL               December 1990

                                                          AE-PFHYA-TE

 


     DEC VUIT[TM] (Visual User Interface Tool),       SSA 32.09.00-A
     Version 1.0 for VMS Systems



               MicroVAX 3900

     VAXstationVAXstation II, VAXstation 2000,
               VAXstation 3100 Series, VAXstation 3200,
               VAXstation 3500, VAXstation 3520,
               VAXstation 3540


     VAXserver:VAXserver 3100, VAXserver 3300,
               VAXserver 3400, VAXserver 3500,
               VAXserver 3600, VAXserver 3602,
               VAXserver 3800, VAXserver 3900

               VAXserver 4000 Model 300

               VAXserver 6000-210, VAXserver 6000-220,
               VAXserver 6000-310, VAXserver 6000-320,
               VAXserver 6000-410, VAXserver 6000-420,
               VAXserver 6000-510, VAXserver 6000-520

     Processors Not Supported

     VAX-11/725, VAX-11/782, MicroVAX I, VAXstation I, VAXstation
     8000

     Block Space Requirements (Block Cluster Size = 1):

     Disk space required for      4,700 blocks
     installation:
                                  (2.4 Mbytes)

     Disk space required for      4,500 blocks
     use (permanent):
                                  (2.3 Mbytes)




                                     2

 


     DEC VUIT[TM] (Visual User Interface Tool),       SSA 32.09.00-A
     Version 1.0 for VMS Systems


     These counts refer to the disk space required on the system
     disk. The sizes are approximate; actual sizes may vary depending
     on the user's system environment, configuration, and software
     options.

     Memory Requirements for DECwindows Support:

     The minimum supported memory for this application running in
     a standalone DECwindows environment with both the client and
     server executing on that same system is 12 MB.

     CLUSTER ENVIRONMENT

     This layered product is fully supported when installed on any
     valid and licensed VAXcluster* configuration without restric-
     tions. The HARDWARE REQUIREMENTS sections of this product's
     Software Product Description and System Support Addendum detail
     any special hardware required by this product.

     *  V5.x VAXcluster configurations are fully described in the
        VAXcluster Software Product Description (28.78.xx) and in-
        clude CI, Ethernet, and Mixed Interconnect configurations.

     SOFTWARE REQUIREMENTS

     For Workstations Running DECwindows:

     o  VMS Operating System V5.3-V5.4 (and necessary components of
        VMS DECwindows)

     o  DECwindows Developer Kit for VMS on OSF/Motif[R] V1.1

     This product may run in either of the following ways:

     o  Standalone execution-running the X11[TM] display server and
        the client application on the same machine.

     o  Remote execution-running the X11 display server and the
        client application on different machines.

                                     3

 


     DEC VUIT[TM] (Visual User Interface Tool),       SSA 32.09.00-A
     Version 1.0 for VMS Systems


     VMS DECwindows is part of the VMS Operating System but must be
     installed separately. Installation of VMS DECwindows gives the
     user the option to install any or all of the following three
     components:

     o  VMS DECwindows Compute Server (Base kit; includes runtime
        support)

     o  VMS DECwindows Device Support

     o  VMS DECwindows Programming Support

     For standalone execution, the following DECwindows components
     must be installed on the machine:

     o  VMS DECwindows Compute Server

     o  VMS DECwindows Device Support

     For remote execution, the following DECwindows components must
     be installed on the machine:

     Server Machine

     o  VMS DECwindows Compute Server

     o  VMS DECwindows Device Support

     Client Machine

     o  VMS DECwindows Compute Server

     VMS Tailoring

     For VMS V5.x systems, the following VMS classes are required for
     full functionality of this layered product:

     o  VMS Required Saveset

     o  Network Support

     o  Programming Support

     o  Utilities

                                     4

 


     DEC VUIT[TM] (Visual User Interface Tool),       SSA 32.09.00-A
     Version 1.0 for VMS Systems


     o  VMS Workstation Support

     For more information on VMS classes and tailoring, refer to
     the VMS Operating System Software Product Description (SPD
     25.01.xx).

     OPTIONAL SOFTWARE

     None


     GROWTH CONSIDERATIONS

     The minimum hardware/software requirements for any future ver-
     sion of this product may be different from the requirements for
     the current version.

     DISTRIBUTION MEDIA

     Tape: 9-track 1600 BPI Magtape (PE), TK50 Streaming Tape

     This product is also available as part of the VMS Consolidated
     Software Distribution on CDROM.

     ORDERING INFORMATION

     Software Licenses: QL-YHCA9-QB
     Software Media: QA-YHCAA-**
     Software Documentation: QA-YHCAA-GZ
     Software Product Services: QT-YHCA*-**

     *  Denotes variant fields. For additional information on avail-
        able licenses, services, and media, refer to the appropriate
        price book.





                                     5

 


     DEC VUIT[TM] (Visual User Interface Tool),       SSA 32.09.00-A
     Version 1.0 for VMS Systems


     The above information is valid at time of release. Please con-
     tact your local Digital office for the most up-to-date informa-
     tion.

     [R]  OSF, OSF/Motif, and Motif are registered trademarks of the
          Open Software Foundation, Inc.

     [TM] X Window System, Version 11 and its derivations (X, X11,
          X Version 11, X Window System) are trademarks of the Mas-
          sachusetts Institute of Technology.

     [TM] The DIGITAL Logo, CI, DEC, DECwindows, MicroVAX, ULTRIX,
          VAX, VAXcluster, VAXft, VAXserver, VAXstation, VMS, and
          VUIT are trademarks of Digital Equipment Corporation.

























                                     6