PRODUCT NAME:  DECvoice Software, Version 1.1           SSA 29.97.01-A


HARDWARE REQUIREMENTS 
									       
Processor Support

VAX:	 VAX 6000 Model 200 Series,
         VAX 6000 Model 300 Series,
	 VAX 6000 Model 400 Series,

	 VAX 8200, VAX 8250, VAX 8300, VAX 8350, VAX 8500, VAX 8530, VAX 8550, 
         VAX 8600, VAX 8650, VAX 8700, VAX 8800, VAX 8810, VAX 8820, VAX 8830, 
         VAX 8840, VAX 8842, VAX 8974, VAX 8978

	 VAX-11/730, VAX-11/750, VAX-11/780, VAX-11/785

MicroVAX:	  MicroVAX II, Microvax 2000, MicroVAX 3100, MicroVAX 3300, 
                  MicroVAX 3400, MicroVAX 3500, MicroVAX 3600, MicroVAX 3800, 
                  MicroVAX 3900

VAXstation:	  VAXstation II, VAXstation 2000, VAXstation 3100 Series, 
                  VAXstation 3200, VAXstation 3500, VAXstation 3520, VAXstation 
                  33540, VAXstation 8000

VAXserver:	  VAXserver 3100, VAXserver 3300, VAXserver 3400, VAXserver 
                  3500, VAXserver 3600, VAXserver 3602, VAXserver 3800, 
                  VAXserver 3900, VAXserver 6000-210, VAXserver 6000-310, 
                  VAXserver 6000-410, VAXserver 6000-420


All VAX, MicroVAX and VAXstation processors lised above are supported 
subject to the following restrictions:

^ All functions requiring communications with or processing by, a 
  DTC04-AA module must be executed on a valid MicroVAX or VAXstation 
  configuration, that is, a configuration containing one or more DTC04-AA 
  modules.  The DTC04-aa hardware is supported only in the BA23 and the 
  BA123 series of enclosures and only when used with the KA630, KA650 or 
  KA655 series of Q-bus processors.

^ The synthesis name pronunciation routines require communications with, 
  and processing by, a DECtalk DTC01 peripheral, DTC03 peripheral or a 
  DECvoice DTC04-AA module.

Processors Not Supported

^ For systems containing a DTC04-AA module, any system containing a 
  processor other than a KA630, KA650 or KA655 Q-bus processor is not 
  supported.

^ VAX-11/725, MicroVAX I, VAXstation I and VAX-11/782 processors are not 
  supported.

Processor Restrictions

^ 64K bytes of available Q-bus I/O memory space for each DTC04-AA module 
  installed in the system.

^ A maximum of sixteen DTC04-AA modules can be supported on a single 
  MicroVAX or VAXstation subject to the following restrictions:

   - The module can be mounted only in a BA23 or BA123 enclosure, or in a 
     multiple BA23 enclosure such as the DTCAA-CA or the H9642 based 
     dual-BA23 MicroVAX systems.
      
   - The number of available Q-bus quad-width slots and subject to 
     available power and loading on the Q-bus.

   - The number of adjacent "B" size mounting slots on the I/O bulkhead. 
     The I/O bulkhead space available on various enclosures limits the 
     number of Telephone Line Interfaces that can be installed on the 
     system.

The following table contains the maximum limits of TLIs and DTC04-AA 
modules.  The actual number of TLIs and DTC04-AA modules that can be 
installed in a system may be further reduced by available Q-bus slots and 
power, or by other hardware or software installed on the system:

     System	   Maximum	  Maximum
     Enclosure	   TLIs		  DTC04-AA 

     DTCAA-CA	     8		     16

     H3490	     3		     6

     H9642-S	     3		     6

     BA123	     2		     4

     BA23	     1		     2

The DTCAA-CA series enclosures, built from the H3490-E bulkhead and three 
BA23 enclosures, support a maximum of eight TLIs; eight TLIs provide 
support for up to sixteen DTC04-AA modules.

The H3490 bulkheads are used in the 630QE dual-BA23 MicroVAX systems, the 
H9642-S expansion enclosure and various other dual-BA23-based cabinetry.  
The H3490 bulkheads support a maximum of three TLIs; three TLIs provide 
support for up to six DTC04-AA modules.

The BA123 enclosures support a maximum of two TLIs; two TLIs provide 
support for up to four DTC04-AA modules.
								         
The single-BA23 enclosures support a maximum of one TLI; one TLI provides 
support for up to two DTC04-AA modules.
  
The performance of the real-time portions of the DTC04-AA system is 
sensitive to processor, VAXcluster and device interrupt latency. 
Degradations will be noticed if DTC04 interrupts are blocked by any other 
software and/or hardware in the MicroVAX or VAXstation system. A 
dedicated MicroVAX system is recommended for optimal DECvoice 
performance.

The DTC04-AA module is not distributed, nor shareable, across nodes in 
the VAXcluster.  The module must reside locally, that is, on the MicroVAX 
or VAXstation processor that performs the calls to the DECvoice 
libraries.
    
Other Hardware Required

If a DTC04-AA Q-bus hardware module is installed in the system, the 
following hardware is required:

^ The base DTC04-AA DECvoice quad-width Q-bus module.

^ An approved country-specific Telephone Line Interface (TLI), the 
  CK-DTC04.  (The TLI is currently only available for the United States 
  and Canada.)  Each TLI supports up to two DTC04-AA modules.

^ A minimum of 150 megabytes of local disk storage.  Digital recommends a 
  KFQSA disk controller and one or more externally mounted RF71 disks for 
  ease of storage expansion, separate disk power supply and the inherent 
  dual-path and dual-host capabilities of the DSSI bus.  A minimum of an 
  RQDX3 disk controller and an RD54 disk is required.

^ A minimum of 8 megabytes of physical memory on any system containing 
  any DTC04-AA modules.

^ A minimum of 16 megabytes of physical memory on any system containing 
  nine or more DTC04-AA modules.

Block Space Requirements (Block Cluster Size = 1):

Disk space required for installation:			    14,431 blocks
								 (7.4 MB)

Disk space required for use (permanent):		    14,431 blocks
								 (7.4 MB)
                                            
These counts refer to the disk space required on the system disk.  The 
sizes are approximations; actual sizes may vary depending on the user's 
system environment, configuration, and software options selected.

OPTIONAL HARDWARE

None

CLUSTER ENVIRONMENT

This layered product is fully supported when installed on any valid and 
licensed VAXcluster*  configuration without restrictions. The HARDWARE 
REQUIREMENTS Sections of this product's Software Product Description and 
System Support Addendum detail any special hardware required by this 
product.

* V5.x VAXcluster configurations are fully described in the VAXcluster 
  Software Product Description (29.78.xx) and include CI, Ethernet, and 
  Mixed Interconnect configurations.

SOFTWARE REQUIREMENTS 

VMS Operating System V5.2

VMS Tailoring

For VMS V5.x systems, a minimum of the VMS Required Saveset is required 
if the DECvoice software is to be used in a run-time only environment, 
that is, no program debugging or development is to be conducted. 

To conduct program development with the DECvoice software, a minimum of 
both the VMS Required Saveset and Programming Support kits is required.

For more information on VMS classes and tailoring, refer to the VMS 
Operating System Software Product Description (SPD 25.01.xx)

OPTIONAL SOFTWARE

The microcode binaries for the DECvoice Software V1.1 Continuous Word  
Speech Recognition Software are included in the DECvoice Software kit. 
The Continuous Word Recognition Software is a separately licensed 
product.

The Continuous Word Recognition Software is licensed on a user/activity 
basis.  When this product is licensed, a pool of license units are made 
available. The specific number of units in the pool varies based on the 
specific license purchased.  The DECvoice Software deducts a fixed number 
of units (100) from the pool whenever the Continuous Word Recognizer is 
made active, that is, when loaded into a DECvoice DTC04-AA module.  These 
units are returned to the pool when the Continuous Word Recognizer 
microcode is rendered inactive, that is, when it is unloaded or otherwise 
made unavailable.  The license unit allocation for the continuous word 
recognizer is not processor tiered; it is not based on CPU capacity.  
Continuous word recognizer licenses are tied only to recognizer activity, 
not to specific DTC04-AA modules.

The isolated word recognizer and the optional Continuous Word Recognizer 
are mutually exclusive; they both cannot be used on the same DECvoice 
module at the same time.  The recognizer in use on a specific DECvoice 
module, when both are licensed, can be switched dynamically under the 
control of a user program.  

Certain versions of these products depend upon a specific version of the 
operating system.  Refer to the System Support Addendum of the product in 
question to determine which version is necessary.

GROWTH CONSIDERATIONS

The minimum hardware/software requirements for any future version of this 
product may be different from the minimum requirements for the current 
version.

DISTRIBUTION MEDIA

Tape:	  9-track 1600 BPI Magtape, TK50 Tape Cartridge
    
This product is also available as part of the VMS Consolidated Software 
Distribution on CDROM.

ORDERING INFORMATION

Software Licenses:  QL-VFUA*-**
Software Media:  QA-VFUA*-**
Software Documentation:  QA-VFUAA-GZ
Software Product Services:  QT-VFUA*-**

Continuous Word Recognizer Licenses: QL-YFCA*-**
Continuous Word Recognizer Services: QT-YFCA*-**

* Denotes variant fields. For additional information on available 
  licenses, services and media, refer to the appropriate price book.

The above information is valid at time of release.  Please contact your 
local Digital office for the most up-to-date information.

The DIGITAL Logo is a registered trademark of Digital Equipment Corporation.
    
VAX, VMS, MicroVAX, VAXstation, VAXserver and DECvoice are trademarks of Digital Equipment Corporation.
    