     System
     Support
     Addendum

     ________________________________________________________________
     ________________________________________________________________

     PRODUCT NAME:   MUXserver 300 Remote Terminal Server for VMS,
     SSA 25.E9.02-A
                     Version 1.2

     HARDWARE REQUIREMENTS

     Processors Supported

     VAX:        VAXft 3000 Model 310

                 VAX 4000 Model 300

                 VAX 6000 Model 200 Series,
                 VAX 6000 Model 300 Series,
                 VAX 6000 Model 400 Series,
                 VAX 6000 Model 500 Series

                 VAX 8200, VAX 8250, VAX 8300, VAX 8350, VAX 8500,
                 VAX 8530, VAX 8550, VAX 8600, VAX 8650, VAX 8700,
                 VAX 8800, VAX 8810, VAX 8820, VAX 8830, VAX 8840,
                 VAX 8842, VAX 8974, VAX 8978

                 VAX 9000 Model 210, VAX 9000 Model 410

                 VAX-11/730, VAX-11/750, VAX-11/780, VAX-11/785

     MicroVAX:   MicroVAX II, MicroVAX 2000, MicroVAX 3100, MicroVAX
                 3300, MicroVAX 3400, MicroVAX 3500, MicroVAX 3600,
                 MicroVAX 3800, MicroVAX 3900



                                  DIGITAL               November 1990

                                                          AE-MJ86E-TE

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2



     VAXstation: VAXstation II, VAXstation 2000, VAXstation 3100
                 Series, VAXstation 3200, VAXstation 3500, VAXstation
                 3520, VAXstation 3540

     VAXserver:  VAXserver 3100, VAXserver 3300, VAXserver 3400,
                 VAXserver 3500, VAXserver 3600, VAXserver 3602,
                 VAXserver 3800, VAXserver 3900

                 VAXserver 6000-210, VAXserver 6000-220, VAXserver
                 6000-310, VAXserver 6000-320, VAXserver 6000-410,
                 VAXserver 6000-420, VAXserver 6000-510, VAXserver
                 6000-520

     Processors Not Supported

     MicroVAX I, VAXstation I, VAXstation II, VAX-11/725, VAX-11/730,
     VAX-11/782, VAXstation 8000

     Processor Restrictions

     The VAX-11/782 processor is not supported by VMS Operating
     System V5.0 or later.

     A TK50 Tape Drive is required for MicroVAX 2000 and VAXstation
     2000 systems.

     Supported Hardware

     The MUXserver/DECmux 300 software runs on the following packaged
     hardware options:

     DSRZC-AA      MUXserver 300 Remote Terminal Server hardware,
                   factory set at 120V, including: one Ethernet
                   connection, two composite link ports, and a super-
                   visory port.



                                     2

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2



     DSRZC-AB      MUXserver 300 Remote Terminal Server hardware,
                   factory set at 240V, including: one Ethernet
                   connection, two composite link ports, and a super-
                   visory port.

     DSRZC-BA      MUXserver 310 Remote Terminal Server hardware,
                   factory set at 120V, including: one Ethernet
                   connection, two composite link ports, and a super-
                   visory port.

     DSRZC-BB      MUXserver 310 Remote Terminal Server hardware,
                   factory set at 240V, including: one Ethernet
                   connection, two composite link ports, and a super-
                   visory port.

     DM308-AA      DECmux 300 Remote Terminal multiplexer hardware,
                   factory set at 120V, including: two composite link
                   ports, and eight EIA 232-D/CCITT V.24 asynchronous
                   lines supporting speeds up to 19.2K bps and modem
                   control.

     DM308-AB      DECmux 300 Remote Terminal multiplexer hardware,
                   factory set at 240V, including: two composite link
                   ports, and eight EIA 232-D/CCITT V.24 asynchronous
                   lines supporting speeds up to 19.2K bps and modem
                   control.

     DM316-AA      DECmux 300 Remote Terminal multiplexer hardware,
                   factory set at 120V, including: two composite
                   link ports, and sixteen EIA 232-D/CCITT V.24
                   asynchronous lines supporting speeds up to 19.2K
                   bps and modem control.






                                     3

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2



     DM316-AB      DECmux 300 Remote Terminal multiplexer hardware,
                   factory set at 240V, including: two composite
                   link ports, and sixteen EIA 232-D/CCITT V.24
                   asynchronous lines supporting speeds up to 19.2K
                   bps and modem control.

     DM316-BA      DECmux 300 Remote Terminal multiplexer hardware,
                   factory set at 120V, including: two composite
                   link ports, and sixteen DEC423 asynchronous lines
                   supporting speeds up to 19.2K bps.

     DM316-BB      DECmux 300 Remote Terminal multiplexer hardware,
                   factory set at 240V, including: two composite
                   link ports, and sixteen DEC423 asynchronous lines
                   supporting speeds up to 19.2K bps.

     DM332-BA      DECmux 300 Remote Terminal multiplexer hardware,
                   factory set at 120V, including: two composite link
                   ports, and thirty-two DEC423 asynchronous lines
                   supporting speeds up to 19.2K bps.

     DM332-BB      DECmux 300 Remote Terminal multiplexer hardware,
                   factory set at 240V, including: two composite link
                   ports, and thirty-two DEC423 asynchronous lines
                   supporting speeds up to 19.2K bps.

     DM308-        DECmux 300 field reconfigured to provide a mix
     Ax + CK       of eight EIA232-D ports with modem control and
     DM316-W7      sixteen DEC423 ports, data leads only.

     DM316-Bx +    DECmux 300 field reconfigured to provide a mix
     CK-DM308-     of eight EIA232-D ports with modem control and
     A7            sixteen DEC423 ports, data leads only.

     Other field upgrades will result in one of the above configura-
     tions and are also supported.


                                     4

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2


     Block Space Requirements (Block Cluster Size = 1):

     Disk space required for      702 blocks
     installation:
                                  (359,000 bytes)

     Disk space required for      620 blocks
     use (permanent):
                                  (317,000 bytes)

     The block space requirements above refer to the disk space
     required on the down-line load host system disk. The sizes are
     approximations; actual sizes may vary depending on the user's
     system environment, configuration, and software options.

     OPTIONAL HARDWARE

     Use the following SHIELDED cables with each of the EIA 232-D
     asynchronous ports on the DECmux 300.

     BC22D         Null modem cable for local terminal or printer
                   connections.

     BC22E         Full modem straight-through cable for asynchronous
                   modem connections.

     BC22F         Full modem straight-through cable for modem con-
                   nections.

     BC22R         Recommended null modem cable for host systems and
                   other devices, including those that use CTS/RTS
                   flow control.

     BC17D         Null modem cable for host systems and other de-
                   vices that do not use CTS/RTS flow control.

     Use DECconnect cables with the DECmux 300 DEC423 ports


                                     5

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2



     H3104-B       DS200 DEC423 CABLE KIT

     H3125         DS200 DEC423 SHIELDED CABLE KIT

     Use the following SHIELDED adapter cables to connect the
     MUXserver 300 and DECmux 300 composite ports to the data commu-
     nication device DCE. Choose the correct cable for the required
     interface standard.

     BC19F-02      2' V.35 Adapter Cable
     BS19D-02      2' V.24 Adapter Cable
     BC19B-02      2' RS449 Adapter Cable
     BC19Y-10      10' Null Modem Unit Interconnect Cable
     BC19C-02      2' X.21 Adapter Cable

     Use the following extension cables with the above adapter ca-
     bles:

     BC19L-xx      V.35 Extension cable
     BC22F-xx      V.24 Extension cable
     BC55D-xx      RS449 Extension cable

     The MUXserver hardware requires both a transceiver drop cable
     and Ethernet connection, H4000 or DELNI, to connect to the Eth-
     ernet physical channel. The following cabinet kits are available
     and are used to increase the number of physical connections of a
     DECmux 300 option.

     Only one upgrade cabinet kit can be installed in the DM308-AA,
     DM308-AB, DM316-BA, DM316-BB options.

     The DM316-AA, DM316-AB, DM332-BA, DM332-BB, options are fully
     configured and cannot be upgraded.

     CK-DM308-     Upgrade cabinet kit, adding eight EIA 232-D/CCITT
     A7            V.24 asynchronous ports, with modem control.


                                     6

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2



     CK-DM316-     Upgrade cabinet kit, adding sixteen DEC423 asyn-
     W7            chronous ports, data leads only.

     Terminals Supported

     The MUXserver/DECmux 300 software supports the following Digital
     terminal devices that have keyboards:

     o  LA34, LA35, LA36, LA38

     o  VT100, VT101, VT102, VT125, VT131

     o  VT220, VT240, VT241

     o  VT320, VT330, VT340, VT240

     Supported terminal parameters are:

     o  Character size 7 data bits with Even, Odd, Mark, or None
        parity

     o  Character size 8 data bits with Even, Odd, or None parity

     The automatic line speed detection (Autobaud) feature is sup-
     ported for either seven-bit characters with even parity or
     eight-bit characters with no parity.

     The MUXserver/DECmux 300 software also supports the following
     Digital Personal Computers (PCs) in both terminal emulation mode
     and terminal file transfer mode:

     o  Professional 325, 350, 380

     o  Rainbow 100A, 100B, 100+

     o  DECmate II, III

     o  VAXmate

     o  DECstation 212, 316, 325, 333

                                     7

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2


     Note: This product is NOT WARRANTED to support non-Digital
     terminal devices or personal computers. However, terminals
     supporting VT200-like characteristics and personal computers
     supporting IBM[R] PC[TM], IBM PC/XT[TM], and IBM PC/AT[TM]
     characteristics may operate with this product.

     Printers Supported

     The MUXserver/DECmux 300 software supports the following Digi-
     tal asynchronous printers when accessed from VAX and MicroVAX
     systems:

     o  LA50, LA75, LA100, LA120, LA210

     o  LJ250

     o  LQP02, LQP03

     o  LN03, LCG01

     o  LG01S, LG02, LG31

     Modems Supported

     For DECmux 300 asynchronous EIA 232-D ports:

     DF01, DF02, DF03, DF112, DF124, DF212, DF242, and DF224 full-
     duplex asynchronous modems for either dial-in or dial-out use.
     Also supported are private- or leased-line modem applications.

     CLUSTER ENVIRONMENT

     This layered product is fully supported when installed on any
     valid and licensed VAXcluster* configuration without restric-
     tions. The HARDWARE REQUIREMENTS sections of this product's
     Software Product Description and System Support Addendum detail
     any special hardware required by this product.

     *  V5.x VAXcluster configurations are fully described in the
        VAXcluster Software Product Description (29.78.xx) and in-
        clude CI, Ethernet, and Mixed Interconnect configurations.

                                     8

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2


     SOFTWARE REQUIREMENTS

     VMS Operating System V5.0-V5.4

     DECnet-VAX V5.0-V5.4

     VMS Tailoring

     For VMS V5.x systems, the following VMS classes are required for
     full functionality of this layered product:

     o  VMS Required Saveset

     o  Network Support

     o  Utilities

     For more information on VMS classes and tailoring, refer to
     the VMS Operating System Software Product Description (SPD
     25.01.xx).

     OPTIONAL SOFTWARE

     None

     GROWTH CONSIDERATIONS

     The minimum hardware/software requirements for any future ver-
     sion of this product may be different from the requirements for
     the current version.

     DISTRIBUTION MEDIA

     9-track 1600 BPI Magtape (PE), TK50 Streaming Tape





                                     9

 


     MUXserver 300 Remote Terminal Server for VMS,     SSA 25.E9.02-A
     Version 1.2


     ORDERING INFORMATION

     Software Media: QA-VT7A*-**
     Software Documentation: QA-VT7AA-GZ
     Software Product Services: QT-VT7A*-**

     *  Denotes variant fields. For additional information on avail-
        able licenses, services and media, refer to the appropriate
        price book.

     The above information is valid at time of release. Please con-
     tact your local Digital office for the most up-to-date informa-
     tion.

     [R]  IBM is a registered trademark of International Business
          Machines Corporation.

     [TM] Bell is a trademark of Bell Telephone Companies.

     [TM] IBM PC, IBM PC/AT, and IBM PC/XT are trademarks of Interna-
          tional Business Machines Corporation.

     [TM] The DIGITAL Logo, DEC, DECconnect, DECmate, DECnet-VAX,
          DECserver, DECstation, DELNI, DESTA, LA50, LA75, LN03, LN03
          PLUS, LN03R, MicroVAX, MicroVMS, MUXserver, Professional,
          Rainbow, VAX, VAXmate, VAXstation, VAXserver, VMS, and VT
          are trademarks of Digital Equipment Corporation.












                                    10