          DIGITAL

          DATATRIEVE-11 Update Cover Letter

          AV-PBGXA-TC

          Software Problem Correction

          For calculations using variables that were declared
          for USAGE REAL, the results were improperly scaled.
          This caused a result to be reported with an improp-
          erly placed decimal point. The magnitude of the error
          depended on the scale of the REAL variable and the
          other factors in the calculation. This problem has been
          corrected.

          New AutoInstall Version

          The version of AutoInstall used with this software is
          V1.1 instead of V1.0 as documented in the V3.3 Instal-
          lation Guide. Therefore, when installing AutoInstall
          on your system, the saveset restoration step should
          specify AUT101 as the saveset filename rather than
          AUT100.

          Installation Prerequisites for RSX-11M and RSX-11M-Plus
          users

          If you are a RSX-11M or RSX-11M-Plus user, you cannot
          simply abort the system startup command file and at-
          tempt the installation from that point. Similarly, if
          you have just completed a system generation, certain
          logical names used by the installation will not have
          meaning yet. You must log out and then log back in to a
          privileged account.

          Before beginning the installation, you should be in
          your default directory. If you issue a SET DEFAULT
          command to another directory before starting the in-
          stallation, Auto-Install may fail.

 


                                                           Page 2



          Documentation correction

          On page 12-7 of the User's Guide, the last sentence on
          the page should indicate a default edit string length
          of 30 characters instead of 10.