             VAX DIBOL
             Installation Guide

             Order Number: AA-L691J-TE



             April 1990

             This document contains instructions for installing VAX DIBOL
             Version 4.1 on the VMS operating system. It also explains how
             to read the online release notes before or after installing
             the product.





             Revision/Update Information:  This revised manual su-
                                           persedes the VAX DIBOL
                                           Installation Guide Version 4.0
                                           (Order Number AA-L691I-TE).

             Operating System and Version: VMS Version 5.0 or higher.
                                           Future releases will
                                           require higher versions.

             Software Version:             VAX DIBOL Version 4.1

             digital equipment corporation
             maynard, massachusetts

 


             ___________________________________________________
             First Printing, July 1986
             Revised, March 1988
             Revised, March 1990

             The information in this document is subject to change without
             notice and should not be construed as a commitment by Digital
             Equipment Corporation.

             Digital Equipment Corporation assumes no responsibility for
             any errors that may appear in this document.

             Any software described in this document is furnished under
             a license and may be used or copied only in accordance with
             the terms of such license. No responsibility is assumed for
             the use or reliability of software or equipment that is not
             supplied by Digital Equipment Corporation or its affiliated
             companies.

             Restricted Rights: Use, duplication, or disclosure by the
             U.S. Government is subject to restrictions as set forth in
             subparagraph (c)(1)(ii)  of the Rights in Technical Data and
             Computer Software clause at DFARS 252.227-7013.

              Digital Equipment Corporation 1988, 1990.

             All rights reserved.
             Printed in U.S.A.

             The postpaid Reader's Comments forms at the end of this docu-
             ment request your critical evaluation to assist in preparing
             future documentation.

             The following are trademarks of Digital Equipment Corporation:

             ALL-IN-1        EduSystem     RT
             DEC             IAS           ULTRIX
             DEC/CMS         MASSBUS       UNIBUS
             DEC/MMS         PDP           VAX
             DECnet          PDT           VAXcluster
             DECmate         P/OS          VMS
             DECsystem-10    Professional  VT
             DECSYSTEM-20    Q-bus         Work Processor
             DECUS           Rainbow
             DECwriter       RSTS
             DIBOL           RSX           DIGITAL

 















                                                                  Contents
          ________________________________________________________________

          Preface .........................................................  v


          ________________________________________________________________
          Chapter 1  Installation Procedure

               1.1   Preparing to Install VAX DIBOL................... 1-1
                     1.1.1 Accessing the Online Release Notes......    1-2
                     1.1.2 Installation Procedure Requirements.....    1-3
                     1.1.3 User Account Quotas and Privileges......    1-5
                     1.1.4 VMS License Management Facility .........   1-5
                     1.1.5 Special Requirements ...................... 1-6
                     1.1.6 Using VMSINSTAL............................ 1-6

               1.2   Installing VAX DIBOL .............................. 1-8
                     1.2.1 Installing VAX DIBOL on a VAXcluster....   1-17

               1.3   After the Installation............................ 1-18

               1.4   Running the Installation Verification
                     Procedure Separately ..............................  1-19

               1.5   Error Conditions...................................  1-19

               1.6   Installing VAX DIBOL as a Shared Image ......... 1-21

               1.7   Determining and Reporting Problems.............. 1-23

                                                                       iii

 







               1.8   Sample Installation ...............................  1-23

               1.9   Files Distributed..................................  1-27
                     1.9.1 File Savesets .............................. 1-30

          ________________________________________________________________
          Tables

               1-1   VAX DIBOL Distributed Files...................... 1-27

               1-2   Contents of the Savesets.......................... 1-31



























          iv

 














                                                                   Preface
          ________________________________________________________________



             This document describes how to install VAX DIBOL Version
             4.1 on the VMS operating system and is intended for sys-
             tem managers. Additional information on performing software
             installations is available in your processor-specific instal-
             lation/operations guide.

             Keep this document with your distribution kit. You will need
             it to reinstall VAX DIBOL should that be necessary.

             The installation procedure is described step-by-step and is,
             for the most part, self-explanatory. The system prompts you
             to answer questions and to change volumes, and waits for you
             to tell it to continue.

             Defaults appear in brackets ([])  throughout the installation
             procedure. Text you type is indicated in red.

             At the back of this document are two Reader's Comments forms.
             If you have any comments about this document, fill out one
             form and mail it; your comments will be considered for the
             next revision of the installation guide.





                                                                         v

 

















                                                                      Chapter 1


                                                         Installation Procedure
               ________________________________________________________________


               ____________________________________________________________

               1.1  Preparing to Install VAX DIBOL

                  Your bill of materials (BOM) specifies the number and con-
                  tents of your media. Be sure to check the contents of your
                  kit against this information. If your kit is damaged or if
                  you find that parts are missing, call your Digital represen-
                  tative.

                  Distribution media must be mounted in numerical order. The
                  installation procedure prompts you to mount the volumes. For
                  more information on how to mount distribution media, see your
                  processor-specific installation/operations guide, which also
                  details several options to the installation procedure.

                  The VAX DIBOL Version 4.1 kit is distributed on the following
                  media:

                  RX01 floppy      9 volumes
                  diskettes

                  TU58 tape        9 volumes
                  cartridges








                                                    Installation Procedure  1-1

 












                  Magtape          1 volume

                  TK50 magtape     1 volume
                  cartridge

                  The kit is installed using the VMSINSTAL command procedure
                  for installing optional software products.

                  The Version 4.1 kit contains one or more distribution vol-
                  umes. Each volume is marked with a unique label that identi-
                  fies each volume in the kit. The volumes in a multi-volume
                  kit must be mounted sequentially in order.

                  The installation basically operates in two phases:

                   1. Phase 1 loads the files from the distribution media to the
                     system disk.

                   2. Phase 2 builds any system-specific files and moves them to
                     the appropriate system directories.

                  VMSINSTAL operates in safety mode if sufficient free blocks
                  are available, so that system failure during the installation
                  leaves the system in a recoverable state. If a sufficient
                  number of blocks are not available, VMSINSTAL operates in
                  an alternate mode that reduces peak utilization. If a system
                  failure occurs in the alternate mode, files on the system
                  disk can be corrupted.

               ____________________________________________________________

               1.1.1  Accessing the Online Release Notes

                  VAX DIBOL provides online release notes. The prompt to dis-
                  play or print the release notes during installation appears
                  in step 5 of the installation procedure when you invoke
                  VMSINSTAL with the OPTIONS N parameter.

                  To obtain the release notes after the installation, type
                  or print the file SYS$HELP:DIBOL041.RELEASE_NOTES. Online
                  help also directs you to the release notes file. After the
                  installation, type the following command:

                    $ HELP DIBOL RELEASE_NOTES

               1-2  Installation Procedure

 










               ____________________________________________________________

               1.1.2  Installation Procedure Requirements

                  The installation takes approximately 5 to 30 minutes, de-
                  pending on the type of media and your system configuration.
                  Before installing VAX DIBOL, you must have the following
                  privileges and resources:

                   o SETPRV privileges, or CMKRNL, WORLD, and SYSPRV privileges

                   o A minimum of 7500 blocks of free disk space during instal-
                     lation; 6500 blocks are used after installation

                   o The number of unused global sections and global pages
                     needed to install DCLTABLES.EXE. Failure to have the
                     sufficient number of unused global sections and global
                     pages could cause the DCL tables to be corrupted in some
                     situations. You must determine these as shown in the
                     following step.

                  To determine the number of global sections and global pages
                  needed, type the following command:

                    $ INSTALL LIST SYS$LIBRARY:DCLTABLES.EXE/GLOBAL/FULL

                    DISK$VAXVMS053:<SYS0.SYSCOMMON.SYSLIB>.EXE
                       DCLTABLES;68     Open Hdr Shar          Lnkbl
                            Entry access count         = 408
                            Current / Maximum shared   = 1 / 5
                            Global section count       = 1 1

                            System Global Sections
                    DCLTABLES_001  (06000000)              PRM SYS      Pagcnt/Refcnt=525/12075 2
                                   Owner:       [SYSTEM]
                                   Protection:  S:RWED,O:RWED,G:RWED,W:RE

                   1 This is the number of global sections needed (1 in this
                     example).

                   2 This is the number of global pages needed (525 in this
                     example).

                  To determine the number of global pages available on your
                  system, invoke the VMS Install Utility by typing the follow-
                  ing command:

                                                    Installation Procedure  1-3

 











                    $ INSTALL LIST/GLOBAL/SUMMARY

                            Summary of Local Memory Global Sections

                    335 Global Sections Used,  32778/2222 Global Pages Used/Unused

                  When you issue this command, the system displays a summary
                  of the number of global sections used, the number of global
                  pages used, and the number of global pages unused. Compare
                  the number of unused Global pages to the number of global
                  pages you need.

                  You can determine the number of global sections available by
                  invoking SYSGEN as follows:

                    $ RUN SYS$SYSTEM:SYSGEN
                    SYSGEN> USE CURRENT
                    SYSGEN> SHOW GBLSECTIONS
                    Parameter Name           Current  Default  Minimum  Maximum  Unit  Dynamic
                    --------- ----           -------  -------  -------  -------  ----  -------
                    GBLSECTIONS                 1000      250       20     4095  Sections
                    SYSGEN> EXIT

                  The first number displayed is the current number of global
                  sections. Subtract the number of global sections used from
                  the value listed under the heading Current (the current limit
                  of global sections on your system). This result is the number
                  of unused global sections available. Compare the number of
                  unused global sections to the number of global sections you
                  need. For example:

                  1000 Current - 335 Used = 665 Unused global sections

                  If there are fewer global pages or global sections available
                  than you need, then perform one of the following steps to
                  obtain the required global pages and/or global sections:

                   o Delete an existing known image with the VMS Install
                     Utility.

                   o Increase the GBLPAGES or GBLSECTIONS system parameter with
                     the VMS System Generation Utility (SYSGEN) by editing the
                     file SYS$SYSTEM:MODPARAMS.DAT. Then invoke the AUTOGEN
                     command procedure, SYS$UPDATE:AUTOGEN.COM. (For more
                     information on the AUTOGEN command procedure, see your
                     processor-specific installation/operations guide.)

               1-4  Installation Procedure

 










               ____________________________________________________________

               1.1.3  User Account Quotas and Privileges

                  To use VAX DIBOL, each account must have TMPMBX and NETMBX
                  privileges and the working set size (WSDEF) must be at least
                  512 pages.

                  Use the VMS Authorize Utility (AUTHORIZE) to compare the
                  current values of these quotas with the requirements for VAX
                  DIBOL. For example, the account used in the following example
                  is the SYSTEM account:

                    $ SET DEFAULT SYS$SYSTEM
                    $ RUN AUTHORIZE
                    UAF> SHOW SYSTEM

                  To change the values of these quotas, use the VMS Authorize
                  Utility's MODIFY command. For more information, see the VMS
                  Authorize Utility Manual.

               ____________________________________________________________

               1.1.4  VMS License Management Facility

                  You must register your VAX DIBOL software license to install
                  VAX DIBOL Version 4.1.

                  The license registration information you need is contained in
                  the Product Authorization Key (PAK) that is shipped with
                  VAX DIBOL. The PAK is a paper certificate that contains
                  information about the license which enables you to run a
                  particular piece of software.

                  During the installation, you are asked if you have registered
                  the VAX DIBOL license and loaded the appropriate authoriza-
                  tion key. You must register and load your license for VAX
                  DIBOL before you start the installation in order to run
                  the Installation Verification Procedure (IVP) and use the
                  software.

                  To register a license, first log in to the system manager's
                  account, SYSTEM. You then have a choice of two ways to per-
                  form the registration:

                   o Invoke the SYS$UPDATE:VMSLICENSE.COM procedure. When it
                     prompts you for information, respond with data from your
                     Product Authorization Key (PAK).

                                                    Installation Procedure  1-5

 











                   o Issue the LICENSE REGISTER command with the appropriate
                     qualifiers that correspond to information on the PAK.

                  For complete information on using LMF, see the manual on the
                  License Management Utility in the VMS documentation set.

               ____________________________________________________________

               1.1.5  Special Requirements

                  If you want VAX DIBOL Language-Sensitive Editor (LSE) sup-
                  port, the LSE license must be installed before you install
                  VAX DIBOL Version 4.1. Ensure the following before using
                  VMSINSTAL:

                   o All users are logged out.

                   o All batch jobs are completed.

                   o Users are prevented from gaining access to the system.

                  If you are installing the VAX DIBOL kit on a clustered system
                  using a shared system disk, you should perform the steps
                  listed at the start of Section 1.1.5 for each system in the
                  cluster. In this case, the installation will place the files
                  in the common system directories, and must be performed only
                  once to update the entire cluster.

                  VAX DIBOL Version 4.1 can be installed on a system root or
                  system disk other than that of the running system. Follow the
                  VMSINSTAL instructions for doing so.

               ____________________________________________________________

               1.1.6  Using VMSINSTAL

                  After you log in to a privileged account to install VAX
                  DIBOL, invoke VMSINSTAL, the command procedure that installs
                  this product. An example of this procedure is shown in steps
                  1 and 2 of Section 1.2

                  The VMSINSTAL command procedure has the following syntax:

                    $ @SYS$UPDATE:VMSINSTAL DIBOL041 ddcu: [OPTIONS N]

               1-6  Installation Procedure

 











                  ddcu:
                  Represents a device name where the distribution volumes will
                  be mounted for the VAX DIBOL installation media; where dd
                  is the device code, c is the controller code, and n is the
                  unit number. It is not necessary to use the console drive
                  to install VAX DIBOL. If you do use the console drive, you
                  should replace any media you removed from the drive. MUA0: is
                  the device name used in examples in this document.

                  OPTIONS N
                  Is an optional parameter you should provide if you want to
                  be prompted to display or print the release notes. If you
                  do not include the OPTIONS N parameter, VMSINSTAL does not
                  prompt you to display or print the release notes. VMSINSTAL
                  permits the use of several other options. For more infor-
                  mation on the other options, see your processor-specific
                  installation/operations guide.

                  If you do not supply the first two parameters, VMSINSTAL
                  prompts you for the product and device names. If you wish to
                  be prompted for the product and device names and to display
                  or print the release notes, type the following:

                    $ @SYS$UPDATE:VMSINSTAL

                  When you invoke VMSINSTAL, it checks the following:

                   o Whether you logged in to a privileged account

                     Digital recommends that you install software from the
                     system manager's account with your default device and
                     directory set to SYS$UPDATE.

                   o Whether you have adequate quotas for installation

                     VMSINSTAL checks for the following quota values:

                      _ ASTLM = 24

                      _ BIOLM = 18

                      _ BYTLM = 18000

                      _ DIOLM = 18

                      _ ENQLM = 30

                      _ FILLM = 20

                   o Whether the following conditions exist

                                                    Installation Procedure  1-7

 











                     If they do, discontinue the conditions before resuming the
                     installation procedure.

                      _ DECnet is up and running

                      _ Users are logged in to the system

                     If VMSINSTAL detects either of these conditions, you will
                     be asked whether you want to continue the installation. If
                     you want to continue, type YES. If you want to stop the
                     installation, press RETURN.

               ____________________________________________________________

               1.2  Installing VAX DIBOL

                  This section contains excerpts from the installation pro-
                  cedure and explains each step. Defaults appear in brackets
                  throughout the installation procedure.

                  To abort the installation procedure at any time, press
                  CTRL/Y. When you press CTRL/Y, the installation procedure
                  deletes all files it has created up to that point and then
                  returns you to DCL level. If you want to retry the installa-
                  tion procedure after pressing CTRL/Y, you must proceed from
                  step 2.

                  Step 1: Log in to a privileged account and set your default
                  device and directory to SYS$UPDATE.

                    Username: SYSTEM
                    Password:
                    $ SET DEFAULT SYS$UPDATE

                  Step 2: Invoke VMSINSTAL.

                    $ @VMSINSTAL DIBOL041 MUA0: OPTIONS N

                          VAX/VMS Software Product Installation Procedure VX.X

                    It is dd-mmm-yyyy at hh:mm.
                    Enter a question mark (?) at any time for help.

                    * Are you satisfied with the backup of your system disk [YES]?

                  If you are satisfied with the backup of your system disk,
                  press RETURN. Otherwise, type NO and press RETURN to discon-
                  tinue the installation.

               1-8  Installation Procedure

 











                  Step 3: Insert the first installation kit volume.

                    Please mount the first volume of the set on MUA0:.
                    * Are you ready? YES
                    The following products will be processed:

                      VAX DIBOL V4.1

                        Beginning installation of VAX DIBOL V4.1 at hh:mm

                    %VMSINSTAL-I-RESTORE, Restoring product saveset A...

                  To indicate that you want to continue the installation, mount
                  volume 1, type YES, and press RETURN.

                  Step 4: Select a release notes option.

                  This step applies only if you specified OPTIONS N in step 2.

                    Release Notes Options:

                        1. Display release notes
                        2. Print release notes
                        3. Both 1 and 2

                        4. Copy release notes to SYS$HELP
                        5. Do not display, print or copy release notes

                    * Select option [3]:

                  If you select option 1, VMSINSTAL displays the release notes
                  online immediately. You can terminate the display at any time
                  by pressing CTRL/C.

                  If you select option 2, VMSINSTAL prompts you for a queue
                  name. Either type a queue name or press RETURN to send the
                  file to the default output print device.

                    * Queue name [SYS$PRINT]:

                  If you select option 3, VMSINSTAL displays the release notes
                  on line immediately. You can terminate the display at any
                  time by pressing CTRL/C. VMSINSTAL then prompts you for a
                  queue name. Either type a queue name or press RETURN to send
                  the file to the default output print device. The VAX DIBOL
                  release notes are then copied to SYS$HELP:DIBOL041.RELEASE_
                  NOTES.

                                                    Installation Procedure  1-9

 











                  If you select option 4, VMSINSTAL copies the release notes to
                  SYS$HELP immediately.

                  If you select option 5, VMSINSTAL does not display, print
                  or copy the release notes; typically this option is selected
                  when the user wants to terminate the installation.

                  Next, VMSINSTAL displays the following prompt:

                    * Do you want to continue the installation [N]?: Y
                    %VMSINSTAL-I-RELMOVED, The product release notes have been successfully
                        moved to SYS$HELP.

                  If you want to continue the installation, type YES and press
                  RETURN. If you type NO or press RETURN, VMSINSTAL discon-
                  tinues the installation. In either case, VMSINSTAL moves the
                  release notes to SYS$HELP.

                  Step 5: Respond to License Registration Queries.

                  VAX DIBOL supports the VMS License Management Facility (LMF).
                  The installation procedure displays license information about
                  your product and then asks if you have registered and loaded
                  your authorization key for VAX DIBOL. The following is an
                  example of such information:

                    Product:       DIBOL
                    Producer:      DEC
                    Version:       4.1

                    Release Date:  26-FEB-1990

                    * Does this product have an authorization key registered and loaded?

                  If you have not registered and loaded your authorization
                  key, you must answer NO to this question. The installation
                  procedure will be completed but you will have to register
                  and load your product authorization key to run the IVP. The
                  following messages will be displayed:

                    VAX DIBOL requires that  the  license  be  installed and
                    loaded  to  run.   The  IVP  will NOT  be run after this
                    installation is complete.  Please run the IVP  by typing
                    @SYS$TEST:DIBOL$IVP.COM. after you have  registered  and
                    loaded  the  VAX DIBOL license.

                    Installation continuing...

               1-10  Installation Procedure

 











                  The installation will then proceed but the Installation
                  Verification Program will not be run and use of the DIBOL
                  compiler will not be permitted until a valid license has been
                  loaded.

                  Step 6: Insert the subsequent installation kit volumes.

                    %BACKUP-I-READYREAD, mount volume 2 on _ddcu: for reading

                    Enter "YES" when ready: YES

                  VMSINSTAL prompts you to insert the next volume and waits for
                  you to type YES after inserting it. If you type NO, VMSINSTAL
                  displays the prompt again. This prompt is displayed only if
                  your installation kit contains more than one volume.

                  Step 7: Select installation options.

                    * Do you want to purge files replaced by this installation [YES]?

                  The directories SYS$EXAMPLES, SYS$HELP, SYS$LIBRARY,
                  SYS$STARTUP, and SYS$SYSTEM may contain previous versions
                  of VAX DIBOL files. These files are replaced during the
                  installation with new files, but the old files are not auto-
                  matically purged. Purging is recommended. In response to the
                  purging prompt, press RETURN to purge the files or type NO to
                  keep them.

                    * Do you want to run the IVP after the installation [YES]?

                  The Installation Verification Procedure (IVP) runs tests
                  to check whether the installation procedure was successful.
                  Press RETURN to run the IVP after the installation. If you do
                  not want to run the IVP, type NO in response to the prompt.

                    * Do you want the entire DIBOL kit installed [YES]?

                  If you answer YES, the entire DIBOL kit (all of the file
                  savesets) will be installed and you will be asked only the
                  following two questions:

                    * Do you want to decompress DBLSTARLET.TLB [YES]?

                  If you answer YES, DBLSTARLET.TLB will be decompressed.

                    * Do you want to supersede the bundled DIBOL routines [NO]?

                                                   Installation Procedure  1-11

 











                  The DIBOL Run-Time Library and the DIBOL Message Manager
                  are bundled with VMS. If you answer YES, the versions of the
                  DIBOL Run-Time Library and the DIBOL Message Manager on the
                  installation kit will replace the existing VMS versions.

                                               NOTE

                      This question will not be asked if you are installing
                      VAX DIBOL Version 4.1 on VMS Version 5.2 or higher.
                      Instead, VMSINSTAL determines if the Run-Time Library
                      on the kit is a newer version than the version on your
                      system. If so, VMSINSTAL replaces the files. If not,
                      VMSINSTAL will not replace your files.

                  If you decide not to install the entire DIBOL kit, the fol-
                  lowing questions are asked:

                    * Do you want to install DBLSTARLET.TLB [YES]?

                  If you answer YES, DBLSTARLET.TLB from saveset C will be
                  installed.

                    * Do you want to decompress DBLSTARLET.TLB [YES]?

                  If you answer YES, DBLSTARLET.TLB will be decompressed.

                    * Do you want the compiler [YES]?

                  If you answer YES, the following question is displayed:

                    * Do you want LSE support [NO]?

                  If you answer YES, the appropriate saveset files are in-
                  stalled.

                    * Do you want the utilities [NO]?

                  If you answer YES, the following message is displayed:

                    The DIBOL kit includes utilities compatible
                    with PDP-11 DIBOLs for sorting, file indexing,
                    and file creating.

                    Please select:
                       1 - To install ALL utilities
                       2 - To install NO utilities
                       3 - To install SELECTED utilities

               1-12  Installation Procedure

 











                    * Please enter choice for utilities [1]:

                  Enter the number which represents your choice for utilities.
                  If you enter 3, the prompting will continue as follows:

                    * Do you want the SORT utilities [NO]?

                    * Do you want the ISAM utility [NO]?

                    * Do you want the message-manager status utility [NO]?

                    * Do you want the menu compiler and utilities [NO]?

                    * Do you want the message files and examples [NO]?

                  If you respond YES to any of the previous prompts, the appro-
                  priate saveset files are installed.

                  When you have responded to all of the prompts, the following
                  message is displayed:

                    +----------------------------------------------------+
                    |      This is the end of the questions required to  |
                    |       install VAX DIBOL.                           |
                    |      After all of the files have been loaded from  |
                    |       the media, installation will complete in     |
                    |       10-25 minutes.                               |
                    +----------------------------------------------------+

                  Step 8: Read informational messages.

                  The VAX DIBOL installation procedure produces a number of
                  informational messages that report on the progress of the
                  installation.

                  Before the IVP is run, any of the following messages are
                  displayed:

                    VMSINSTAL-I-RESTORE, Restoring product saveset  B...
                    VMSINSTAL-I-RESTORE, Restoring product saveset  C...
                    VMSINSTAL-I-RESTORE, Restoring product saveset  D...
                    VMSINSTAL-I-RESTORE, Restoring product saveset  E...
                    VMSINSTAL-I-RESTORE, Restoring product saveset  F...
                    VMSINSTAL-I-RESTORE, Restoring product saveset  G...

                  These messages indicate that VMSINSTAL is retrieving saveset
                  files from the media. Individual saveset messages are dis-
                  played depending on the options selected during installation.

                                                   Installation Procedure  1-13

 











                  During the installation, the IVP programs are moved to
                  [SYSTEST.DIBOL]. If [SYSTEST.DIBOL] does not exist, the
                  directory will be automatically created and the following
                  message displayed:

                    VMSINSTAL-I-SYSDIR, This product creates system directory
                    [SYSTEST.DIBOL].

                  If you are installing DIBOL on the boot node of a clus-
                  ter, the following message will also be displayed if
                  [SYSTEST.DIBOL] had to be created:

                    If you intend to execute this layered product on other nodes of your
                    VAXcluster, and you have the appropriate software license, you must
                    prepare the system-specific roots on the other nodes by
                    issuing the following command on each node (using a suitably
                    privileged account):

                    $ CREATE/DIRECTORY SYS$SPECIFIC:[SYSTEST.DIBOL]

                        %VMSINSTAL-I-MOVEFILES, files will now be moved to their
                        target directories...

                  If the installation procedure is successful, the new or
                  modified files are moved to their target directories.

                  The following message is displayed immediately before the
                  IVP program is run and indicates the process ID of the DIBOL
                  message manager utility which has been started for the IVP.
                  In this example, the process ID is 00030000D.

                    RUN-S-PROC_ID, identification of created process is 00030000D

                  The SYS$HELP:HELPLIB.HLB and SYS$LIBRARY:DCLTABLES.EXE files
                  are updated to include the new versions of the VAX DIBOL HELP
                  text and the DIBOL command line definition.

                    This installation will add the following files:

                    SYS$SYSTEM: DIBOL85.EXE
                                DBLISMUTL.EXE
                                DBLMSGMGR.EXE
                                DBLSORT.EXE
                                DBLSORT2.EXE
                                DBLSORTG.EXE
                                DBLSTATUS.EXE
                                DBLMNUGEN.EXE

               1-14  Installation Procedure

 











                    SYS$LIBRARY: DBLRTL.EXE
                                 DBLSORTM.DBL
                                 DBLRTL.OPT
                                 DBLOSSL.OLB
                                 DBLUESL.OLB
                                 DBLTEXT.TLB
                                 DBLSTARLET.TLB

                    SYS$STARTUP: DBLSTRTUP.COM

                    SYS$HELP: DIBOL.HLB
                              DIBOL041.RELEASE_NOTES

                    SYS$MESSAGE: DIB85MSG.EXE
                                 DBLRTLMSG.EXE
                                 DIB85MSG.MSG
                                 DBLISMMSG.MSG
                                 DBLMGNMSG.MSG
                                 DBLMGRMSG.MSG
                                 DBLMNUMSG.MSG
                                 DBLRTLMSG.MSG
                                 DBLSRTMSG.MSG
                                 DBLSTSMSG.MSG

                    SYS$UPDATE: DBLREADME.LIS
                                DBLTNMBRS.COM

                    SYS$EXAMPLES: DBLDBGINI.COM
                                  DSMNT.DBL
                                  MNT.DBL
                                  SORT.DBL
                                  DIBOL85.CLD
                                  DBLIVPDET.EXE

                    SYS$SYSROOT:[SYSTEST] DIBOL$IVP.COM

                    SYS$SYSROOT:[SYSTEST.DIBOL]
                            DBLIVP.DBL
                            DBLIVPSUB.DBL
                            DBLIVPFUN.DBL
                            DBLIVPDET.DBL

                  If you typed YES in response to the prompt that requests
                  a file purge at step 7, previous versions of the VAX DIBOL
                  files are now purged.

                                                   Installation Procedure  1-15

 











                  Step 9: Observe the Installation Verification Procedure.

                  If you chose to run the IVP in step 7, VMSINSTAL now calls
                  the IVP to verify that VAX DIBOL was installed successfully.
                  The following is a sample run of the IVP:

                    +--------------------------------------------------------------------+
                    | Starting VAX DIBOL Version 4.1 Installation Verification Program   |
                    +--------------------------------------------------------------------+
                    |       Seventeen tests follow                                       |
                    |       Completed test number 01  (OPEN, DISPLAY)                    |
                    |       Completed test number 02  (WRITES, FLUSH)                    |
                    |       Completed test number 03  (READS, FIND)                      |
                    |       Completed test number 04  (READ by RFA)                      |
                    |       Completed test number 05  (Error handling)                   |
                    |       Completed test number 06  (Arithmetic)                       |
                    |       Completed test number 07  (Booleans)                         |
                    |       Completed test number 08  (CALL, RETURN)                     |
                    |       Completed test number 09  (Substrings, MD Arrays)            |
                    |       Completed test number 10  (Functions)                        |
                    |       Completed test number 11  (UESL XCALLS)                      |
                    |       Starting SLEEP at 13:23:58.96 for 4.5 seconds                |
                    |       Finished SLEEP at 13:24:03.81                                |
                    |       Completed test number 12  (SLEEP)                            |
                    |       Completed test number 13  (XCALL MONEY, Edit-strings)        |
                    |       Completed test number 14  (XCALL to a DIBOL subroutine)      |
                    |       Completed test number 15  (LOCASE)                           |
                    |       Completed test number 16A  (SEND, RECV: Part 1)              |
                    |       Next section may take up to two minutes                      |
                    |       Completed test number 16B  (SEND, RECV: Part 2)              |
                    |       Completed test number 17  (FOR, USING)                       |
                    +--------------------------------------------------------------------+
                    |       Date is 23-APR-90        Time is 13:24                       |
                    |       Job number is 1669       Terminal number is  618             |
                    |       DIBOL Run-Time Library Version is "VAX/VMS  V4.01"           |
                    +--------------------------------------------------------------------+
                    |       VAX DIBOL Version 4.1 IVP successfully completed             |
                    +---------------------------------------------------------------------
                    Installation of DIBOL V4.1 completed at 13:24






               1-16  Installation Procedure

 











                  Step 10: End the installation procedure.

                       Installation of VAX DIBOL V4.1 completed at hh:mm

                       VMSINSTAL procedure done at hh:mm

                    $ LOGOUT
                    SYSTEM     logged out at dd-mmm-yyyy hh:mm:ss.ss

                  When the product installation procedure is complete, you
                  can choose to install more products or to log out (as shown
                  here.) If you removed any media from the console drive before
                  beginning the installation, you should replace it now.

                  VMSINSTAL deletes or changes entries in the process symbol
                  tables during the installation. Therefore, if you are going
                  to continue using the system manager's account and you want
                  to restore these symbols, you should log out and log in
                  again.

               ____________________________________________________________

               1.2.1  Installing VAX DIBOL on a VAXcluster

                  If you want to run VAX DIBOL Version 4.1 on multiple nodes of
                  a VAXcluster, first check to see that you have the appropri-
                  ate software license.

                  If you have installed the VAX DIBOL kit on a clustered system
                  using a shared system disk, you should perform the following
                  steps on each system in the cluster (other than the one used
                  for the installation) to ensure that the other systems in the
                  cluster access the correct files.

                   1. Log in to the system manager's account on the system to be
                     updated.

                   2. Issue the LICENSE LOAD command to activate the license
                     on each node in the VAXcluster on which VAX DIBOL is to
                     be executed, as described in the VMS License Management
                     Utility Manual.

                                                 NOTE

                         As of Version 4.1, VAX DIBOL uses the VMS License
                         Management Facility (LMF) to register the product
                         online. If VAX DIBOL is registered using LMF, and
                         it is to be used on a node in a VAXcluster other

                                                   Installation Procedure  1-17

 











                         than the node on which the installation is taking
                         place, then the user must issue the LICENSE LOAD
                         command on each node on which the product is to be
                         executed.

                   3. Replace the known image entries for DCLTABLES and DBLRTL
                     (if installed) using the INSTALL utility.

                       $INSTALL
                       INSTALL>REPLACE SYS$SHARE:DCLTABLES
                       INSTALL>REPLACE SYS$SHARE:DBLRTL
                       INSTALL>EXIT

                   4. Restart the DIBOL message manager by executing the follow-
                     ing command:

                       $@SYS$STARTUP:DBLSTRTUP RESTART

                  If you have installed other DIBOL files which have been
                  replaced by the Version 4.1 installation, you should use
                  now INSTALL to replace those known image entries as well.
                  See Section 1.6, Installing VAX DIBOL as a Shared Image for a
                  list of those files.

               ____________________________________________________________

               1.3  After the Installation

                  VAX DIBOL is now installed and can be invoked by all users
                  with the DIBOL command.

                  The installation procedure modifies the DCL command table so
                  that the DIBOL command is recognized and processed. However,
                  the previous command table is still in effect for those users
                  who are currently logged in. All logged-in users who want to
                  use the new DIBOL command must log out of the system and log
                  in again. After installation, SYS$STARTUP:SYSTARTUP_V5.COM
                  must be edited to include SYS$STARTUP:DBLSTRTUP.COM, which
                  must be excuted to start the DIBOL Message Manager.






               1-18  Installation Procedure

 










               ____________________________________________________________

               1.4  Running the Installation Verification Procedure Separately

                  The Installation Verification Procedure (IVP) is usually run
                  at installation. If you want to run the IVP separately to
                  ensure the integrity of installed files if system problems
                  occur, execute the following command procedure:

                    $ @SYS$TEST:DIBOL$IVP.COM

                  If the IVP fails for any reason, the following message is
                  displayed:

                    The VAX DIBOL V4.1 Installation Verification Procedure failed.

               ____________________________________________________________

               1.5  Error Conditions

                  If the installation procedure fails for any reason, a message
                  like the one following is displayed:

                    %VMSINSTAL-E-INSFAIL, The installation of VAX DIBOL V4.1 has failed.

                  An error during the installation can occur if one or more of
                  the following conditions exist:

                   o Operating system version is incorrect.

                   o Prerequisite software version is incorrect.

                   o Process quotas required by VMSINSTAL are incorrect (see
                     Section 1.1.6).

                   o The VMS HELP library is currently in use.

                  For descriptions of the error messages generated by these
                  conditions, see the VMS System Messages and Recovery
                  Procedures Reference Volume, your processor-specific in-
                  stallation/operations guide, or the VMS License Management
                  Utility Manual.

                  If you are notified that any of these conditions exist, you
                  should take the appropriate action as described in the mes-
                  sage. You may need to change a system parameter or increase
                  an authorized quota value.

                                                   Installation Procedure  1-19

 











                  If the installation fails, you must restart the installation
                  procedure from step 2. If the installation fails due to
                  an IVP failure, see Section 1.7, Determining and Reporting
                  Problems.

                  The following is a list of error messages that may be gener-
                  ated by the VAX DIBOL installation procedure:

                        VAX DIBOL requires that  the  license  be  installed and
                        loaded  to  run.   The  IVP  will NOT  be run after this
                        installation is complete.  Please run the IVP  by typing
                        @SYS$TEST:DIBOL$IVP.COM. after you have  registered  and
                        loaded  the  VAX DIBOL license.

                        Installation continuing...

                        Explanation: The installation will then proceed but the
                        Installation Verification Program will not be run and
                        use of the DIBOL compiler will not be permitted until a
                        valid license has been loaded.

                        VAX DIBOL V4.1 is not being installed with VAX
                        Language-Sensitive  Editor  support because the Editor's
                        license is not registered and loaded on your system. If
                        you want the VAX Language-Sensitive Editor support
                        you must do the following:

                        1. Register and load the VAX Language-Sensitive Editor license

                        2. Reinstall VAX DIBOL V4.1

                        Explanation: If the user requests LSE support, the
                        procedure checks to ensure that LSE is installed prior
                        to continuing with this section of the installation.
                        Following the check for LSE installation, the procedure
                        will verify the presence of a valid LSE license. If
                        a valid license is not found, LSE support will not
                        be installed and this message will be displayed. If a
                        valid license is found, LSE support will be installed.

                        This kit requires Version 5.0 or later of VMS

                        Explanation: Upgrade the version of VMS to Version 5.0
                        or higher.

               1-20  Installation Procedure

 











                        The file CDDSHR.EXE was not found

                        Explanation: This file is supplied by VMS. Determine
                        why the file was not there and restore the file.

                        The file CRFSHR.EXE was not found

                        Explanation: This file is supplied by VMS. Determine
                        why the file was not there and restore the file.

               ____________________________________________________________

               1.6  Installing VAX DIBOL as a Shared Image

                  If VAX DIBOL will be used extensively on your system, you
                  can reduce the system overhead and memory requirements by in-
                  stalling it as a shared image. There are four files that can
                  improve memory usage and performance if they are installed
                  as shared images. Either the Run-Time System files or the
                  Compiler files or both sets of files can be installed.

                  To install the files as a shared image, use the VMS Install
                  Utility while you are logged in to a privileged account. If
                  errors occur, see VMS System Messages and Recovery Procedures
                  Reference Volume.

                  First, determine the number of available global pages
                  and global sections on your system. See Section 1.1.2,
                  Installation Procedure Requirements for information on how to
                  do this. The following table lists the number of global sec-
                  tions and approximate number of global pages for the Run-Time
                  System files and the Compiler files.

                  _____________________________________________________________
                                           Number of   Approximate Number
                                           GBLSECTIONS of GBLPAGES
                  Files____________________Needed______Needed__________________

                  Run-Time_Library_Files_______________________________________

                  SYS$SHARE:DBLRTL.EXE     1           225

                  SYS$MESSAGE:DBLRTLMSG.EXE1           35


                                                   Installation Procedure  1-21

 










                  _____________________________________________________________
                                           Number of   Approximate Number
                                           GBLSECTIONS of GBLPAGES
                  _____________________________________________________________

                  Compiler_Files_______________________________________________

                  SYS$SYSTEM:DIBOL85.EXE   2           285

                  SYS$MESSAGE:DIB85MSG.EXE 1           30

                  _____________________________________________________________

                  _____________________________________________________________
                  Total____________________5___________575_____________________

                  Then, invoke the VMS Install Utility and install the VAX
                  DIBOL files as shared images by typing the following commands
                  (replacing <filename>) with the file to be replaced:

                    $ RUN SYS$SYSTEM:INSTALL

                    INSTALL> ADD SYS$SYSTEM:<filename>.EXE/OPEN/SHARED
                       .
                       .
                       .
                    INSTALL> EXIT

                  Then, update the system startup file to install VAX DIBOL.

                  To ensure that VAX DIBOL is installed as a shared image each
                  time the system is bootstrapped, include the following lines
                  in SYS$STARTUP:SYSTARTUP_V5.COM (the site-specific startup
                  file):

                    $ INSTALL
                    ADD SYS$SYSTEM:<filename>.EXE/OPEN/SHARED
                       .
                       .
                       .
                    EXIT





               1-22  Installation Procedure

 










               ____________________________________________________________

               1.7  Determining and Reporting Problems

                  If an error occurs while you are using VAX DIBOL and you
                  believe that the error is caused by a problem with VAX DIBOL,
                  take one of the following actions:

                   o If you purchased VAX DIBOL within the past 90 days and you
                     think the problem is caused by a software error, you can
                     submit a Software Performance Report (SPR).

                   o If you have a Basic or DECsupport Software Agreement,
                     you should call your Customer Support Center. With these
                     services, you receive telephone support that provides
                     high-level advisory and remedial assistance. For more
                     information, contact your local Digital representative.

                   o If you have a Self-Maintenance Software Agreement, you can
                     submit a Software Performance Report (SPR).

                  If you find an error in the VAX DIBOL documentation, you
                  should fill out and submit a Reader's Comments form from the
                  back of the document which contained the error. Include the
                  section and page number where the error was found.

               ____________________________________________________________

               1.8  Sample Installation

                  This section contains a sample installation of VAX DIBOL.
                  Note that this is only a sample.

                    $ @SYS$UPDATE:VMSINSTAL OPTIONS N

                          VAX/VMS Software Product Installation Procedure VX.X

                    It is 23-APR-1990 at 13:15

                    Enter a question mark (?) at any time for help.

                    * Are you satisfied with the backup of your system disk [YES]? YES

                    Where will the distribution volumes be mounted: CSA1:.
                    * Are you ready? YES

                    Enter the products to be processed from the first distribution
                    volume set.
                    * Products:DIBOL

                    The following products will be processed:

                                                   Installation Procedure  1-23

 











                      VAX DIBOL V4.1

                          Beginning installation of DIBOL V4.1 at 13:16

                    VMSINSTAL-I-RESTORE, Restoring product saveset A...

                    Release Notes Options:

                        1. Display release notes
                        2. Print release notes
                        3. Both 1 and 2

                        4. Copy release notes to SYS$HELP
                        5. Do not display, print or copy release notes

                    * Select option [3]:

                    * Queue name [SYS$PRINT]:

                    * Do you want to continue the installation [N]?: Y
                    %VMSINSTAL-I-RELMOVED, The product release notes have been successfully
                        moved to SYS$HELP.

                          VAX DIBOL Version V4.1 Installation

                    Product:       DIBOL
                    Producer:      DEC
                    Version:       4.1

                    Release Date:  26-FEB-1990

                    * Does this product have an authorization key registered and
                    loaded? YES

                    * Do you want to purge files replaced by this installation [YES]?

                    * Do you want to run the IVP after the installation [YES]?

                    * Do you want the entire DIBOL kit installed [YES]?  NO

                    * Do you want to install DBLSTARLET.TLB [YES]? YES
                    * Do you want to decompress DBLSTARLET.TLB [YES]? YES
                    * Do you want the compiler [YES]? YES
                    * Do you want LSE support [NO]? YES
                    * Do you want the utilities [NO]? YES

                    The DIBOL kit includes utilities compatible
                    with PDP-11 DIBOLs for sorting, file indexing,
                    and file creating.

               1-24  Installation Procedure

 











                    Please select:
                       1 - To install ALL utilities
                       2 - To install NO utilities
                       3 - To install SELECTED utilities

                    * Please enter choice for utilities [1]:3
                    * Do you want the SORT utilities [NO]? YES
                    * Do you want the ISAM utility [NO]? YES
                    * Do you want the message-manager status utility [NO]? YES
                    * Do you want the ISAM utility [NO]? YES
                    * Do you want the menu compiler and utilities [NO]? YES
                    * Do you want the message files and examples [NO]? YES

                    +---------------------------------------------------------+
                    |      This is the end of the questions required to       |
                    |       install VAX DIBOL.                                |
                    |      After all of the files have been loaded from       |
                    |       the media, installation will be completed in      |
                    |       10-25 minutes.                                    |
                    +---------------------------------------------------------+

                        VMSINSTAL-I-RESTORE, Restoring product saveset  B...
                        VMSINSTAL-I-RESTORE, Restoring product saveset  C...
                        VMSINSTAL-I-RESTORE, Restoring product saveset  D...
                        VMSINSTAL-I-RESTORE, Restoring product saveset  E...
                        VMSINSTAL-I-RESTORE, Restoring product saveset  F...
                        VMSINSTAL-I-RESTORE, Restoring product saveset  G...

                    If you intend to execute this layered product on other nodes of your
                    VAXcluster, and you have the appropriate software license, you must
                    prepare the system-specific roots on the other nodes by
                    issuing the following command on each node (using a suitably
                    privileged account):

                    $ CREATE/DIRECTORY SYS$SPECIFIC:[SYSTEST.DIBOL]

                     %VMSINSTAL-I-MOVEFILES, files will now be moved to their
                        target directories...







                                                   Installation Procedure  1-25

 











                    RUN-S-PROC_ID, identification of created process is 00030000D

                    +--------------------------------------------------------------------+
                    | Starting VAX DIBOL Version 4.1 Installation Verification Program   |
                    +--------------------------------------------------------------------+
                    |       Seventeen tests follow                                       |
                    |       Completed test number 01  (OPEN, DISPLAY)                    |
                    |       Completed test number 02  (WRITES, FLUSH)                    |
                    |       Completed test number 03  (READS, FIND)                      |
                    |       Completed test number 04  (READ by RFA)                      |
                    |       Completed test number 05  (Error handling)                   |
                    |       Completed test number 06  (Arithmetic)                       |
                    |       Completed test number 07  (Booleans)                         |
                    |       Completed test number 08  (CALL, RETURN)                     |
                    |       Completed test number 09  (Substrings, MD Arrays)            |
                    |       Completed test number 10  (Functions)                        |
                    |       Completed test number 11  (UESL XCALLS)                      |
                    |       Starting SLEEP at 13:23:58.96 for 4.5 seconds                |
                    |       Finished SLEEP at 13:24:03.81                                |
                    |       Completed test number 12  (SLEEP)                            |
                    |       Completed test number 13  (XCALL MONEY, Edit-strings)        |
                    |       Completed test number 14  (XCALL to a DIBOL subroutine)      |
                    |       Completed test number 15  (LOCASE)                           |
                    |       Completed test number 16A  (SEND, RECV: Part 1)              |
                    |       Next section may take up to two minutes                      |
                    |       Completed test number 16B  (SEND, RECV: Part 2)              |
                    |       Completed test number 17  (FOR, USING)                       |
                    +--------------------------------------------------------------------+
                    |       Date is 23-APR-90        Time is 13:24                       |
                    |       Job number is 1669       Terminal number is  618             |
                    |       DIBOL Run-Time Library Version is "VAX/VMS  V4.01"           |
                    +--------------------------------------------------------------------+
                    |       VAX DIBOL Version 4.1 IVP successfully completed             |
                    +---------------------------------------------------------------------
                    Installation of DIBOL V4.1 completed at 13:24

                    Enter the products to be installed from the next distribution
                    volume set.

                    * Products:EXIT

                       VMSINSTAL procedure done at 13:25

                    $ LOGOUT

               1-26  Installation Procedure

 










               ____________________________________________________________

               1.9  Files Distributed

                  The files listed in Table 1-1 are distributed as part of VAX
                  DIBOL Version 4.1 and are included in a full installation.
                  You can save space on your system disk by removing any files
                  which are not used in your system environment. The DIBOL.RTL
                  (DBLRTL.EXE) is required to execute any DIBOL program, and
                  the message manager utility is required for SEND/RECV and
                  for XCALL WAIT. The Language-Sensitive Editor (LSE) support
                  files (DIBOL.ENV and LSEUPDATE_ENV.TPU) are required for
                  installation. When the installation procedure is successfully
                  completed, these files are automatically deleted.

                  Table 1-1:  VAX DIBOL Distributed Files
                  _____________________________________________________________
                  Directory___Filename______________Description________________

                  SYS$SYSTEM  DIBOL85.EXE           VAX DIBOL compiler image

                              DBLISMUTL.EXE         DIBOL ISAM utility image

                              DBLMSGMGR.EXE         DIBOL message manager
                                                    utility image

                              DBLSORT.EXE           DIBOL sort utility (command
                                                    phase) image

                              DBLSORT2.EXE          DIBOL sort utility
                                                    (sort/merge phase) image

                              DBLSORTG.EXE          DIBOL SORTG/M utility
                                                    (command phase) image

                              DBLSTATUS.EXE         DIBOL status utility image

                              DBLMNUGEN.EXE         DIBOL menu generator util-
                                                    ity image
                  _____________________________________________________________
                                                       (continued on next page)





                                                   Installation Procedure  1-27

 











                  Table 1-1 (Cont.):  VAX DIBOL Distributed Files
                  _____________________________________________________________
                  Directory___Filename______________Description________________

                  SYS$LIBRARY DBLRTL.EXE            DIBOL Run-Time Library
                                                    shareable image

                              DBLSORTM.DBL          DIBOLSORTG/M utility
                                                    (sort/merge phase) source

                              DBLRTL.OPT            DIBOL RTL linker options
                                                    file

                              DBLOSSL.OLB           DIBOL OSSL library

                              DBLUESL.OLB           DIBOL UESL library

                              DBLTEXT.TLB           DIBOL Text library

                              DBLSTARLET.TLB        DIBOL STARLET Text library
                                                    of
                                                    SYS$LIBRARY:STARLET.MLB

                  SYS$STARTUP DBLSTRTUP.COM         DIBOL message manager
                                                    utility startup command
                                                    procedure

                  SYS$HELP    DIBOL.HLB             Extended DIBOL help library

                              DIBOL041.RELEASE_     Release Notes for VAX DIBOL
                              NOTES                 Version 4.1

                  SYS$MESSAGE DIB85MSG.EXE          VAX DIBOL compiler error
                                                    message file

                              DBLRTLMSG.EXE         DBLRTL and utilities error
                                                    message file
                  _____________________________________________________________
                                                       (continued on next page)






               1-28  Installation Procedure

 











                  Table 1-1 (Cont.):  VAX DIBOL Distributed Files
                  _____________________________________________________________
                  Directory___Filename______________Description________________

                              DIB85MSG.MSG          Source file for compiler
                                                    error messages

                              DBLISMMSG.MSG         Source file for DBLISMUTL
                                                    messages

                              DBLMGNMSG.MSG         Source file for DBLMNUGEN
                                                    messages

                              DBLMGRMSG.MSG         Source file for DBLMSGMGR
                                                    messages

                              DBLMNUMSG.MSG         Source file for MENU sub-
                                                    routine messages

                              DBLRTLMSG.MSG         Source file for DBLRTL
                                                    messages

                              DBLSRTMSG.MSG         Source file for DBLSORT
                                                    messages

                              DBLSTSMSG.MSG         Source file for DBLSTATUS
                                                    messages

                  SYS$UPDATE  DBLREADME.LIS         Miscellaneous information

                              DBLTNMBRS.COM         Terminal number table
                                                    update procedure

                  SYS$EXAMPLESDBLDBGINI.COM         Sample VAX/VMS Symbolic
                                                    Debugger initialization
                                                    file
                  _____________________________________________________________
                                                       (continued on next page)







                                                   Installation Procedure  1-29

 











                  Table 1-1 (Cont.):  VAX DIBOL Distributed Files
                  _____________________________________________________________
                  Directory___Filename______________Description________________

                              DSMNT.DBL             Sample VAX DIBOL programs
                              MNT.DBL
                              SORT.DBL

                              DIBOL85.CLD           DIBOL-85 Command Language
                                                    Definitions file

                              DBLIVPDET.EXE         Installation Verification
                                                    Program executable file

                  SYS$SYSROOT:[SYSTEST]

                              DIBOL$IVP.COM         Command file for Installation
                                                    Verification Procedure

                  SYS$SYSROOT:[SYSTEST.DIBOL]

                              DBLIVP.DBL            Sample Installation
                              DBLIVPSUB.DBL         Verification Procedure
                              DBLIVPFUN.DBL         programs
                              DBLIVPDET.DBL              .
                                                         .
                  _______________________________________._____________________


               ____________________________________________________________

               1.9.1  File Savesets

                  Files are classified into savesets A through G. When you are
                  installing the DIBOL kit, you can choose a full installation
                  (savesets A through G) or select from savesets C through G
                  (all installations contain savesets A and B).

                  The contents of the savesets are as follows:






               1-30  Installation Procedure

 











                  Table 1-2:  Contents of the Savesets
                  _____________________________________________________________
                  Saveset_A________Installation________________________________

                  KITINSTAL.COM    temporary

                  DIBOL041.RELEASE_NOTES

                  DIBOL$IVP.COM

                  DBLIVP.DBL       IVP routines

                  DBLIVPSUB.DBL    IVP source
                                        .
                                        .
                                        .

                  DBLIVPFUN.DBL

                  DBLIVPDET.DBL

                  DBLIVP.EXE

                  DBLIVPDET.EXE    temporary IVP

                  _____________________________________________________________
                  Saveset_B________Run-Time_Library____________________________

                  DBLRTL.EXE       run-time system

                  DBLRTLMSG.EXE    error message files

                  DBLOSSL.OLB      OSSL library

                  DBLUESL.OLB      UESL library

                  DBLREADME.LIS    "read me" text
                  _____________________________________________________________
                                                       (continued on next page)






                                                   Installation Procedure  1-31

 











                  Table 1-2 (Cont.):  Contents of the Savesets
                  _____________________________________________________________
                  Saveset_B________Run-Time_Library____________________________

                  DBLSTRTUP.COM    message manager utility startup

                  DBLTNMBRS.COM    change default terminal numbers

                  DIBOL.HLB        extended help library

                  DBLMSGMGR.EXE    message manager

                  _____________________________________________________________
                  Saveset_C________Compiler____________________________________

                  DIBOL85.CLD      command line description

                  DIBOL85.EXE      native mode compiler

                  DIBOLCMD.HLP     DCL help

                  DIB85MSG.EXE     compiler error messages

                  DBLRTL.OPT       link options file

                  DBLTEXT.TLB      text library

                  DBLDBGINI.COM    DEBUG initialization file

                  DBLSTARLET.TLB   STARLET text library

                  _____________________________________________________________
                  Saveset_D________LSE_________________________________________

                  DIBOL.ENV        environment file-temporary

                  LSEUPDATE_       used to insert environment file-temporary
                  ENV.TPU
                  _____________________________________________________________
                                                       (continued on next page)





               1-32  Installation Procedure

 











                  Table 1-2 (Cont.):  Contents of the Savesets
                  _____________________________________________________________
                  Saveset_E________Utilities___________________________________

                  DBLSORT.EXE      SORT

                  DBLSORT2.EXE     SORT

                  DBLSORTG.EXE     SORT

                  DBLSORTM.EXE     SORT

                  DBLISMUTL.EXE    ISAM utility

                  DBLSTATUS.EXE    message manager status utility

                  _____________________________________________________________
                  Saveset_F________Menu________________________________________

                  DBLMNUGEN.EXE    menu generator

                  _____________________________________________________________
                  Saveset_G________Menu________________________________________

                  DBLRTLMSG.MSG    Source file for DBLRTL messages

                  DBLISMMSG.MSG    Source file for DBLISMUTL messages

                  DBLMGNMSG.MSG    Source file for DBLMNUGEN messages

                  DBLMGRMSG.MSG    Source file for DBLMSGMGR messages

                  DBLMNUMSG.MSG    Source file for MENU subroutine messages

                  DBLSRTMSG.MSG    Source file for DBLSORT messages

                  DBLSTSMSG.MSG    Source file for DBLSTATUS messages

                  DIB85MSG.MSG
                  _____________________________________________________________
                                                       (continued on next page)




                                                   Installation Procedure  1-33

 











                  Table 1-2 (Cont.):  Contents of the Savesets
                  _____________________________________________________________
                  Saveset_G________Menu________________________________________

                  DSMNT.DBL

                  MNT.DBL

                  SORT.DBL_____________________________________________________


                  If you install Saveset G, the DBLIVP*.DBL from Saveset A are
                  moved to the SYS$EXAMPLES directory and saved. Otherwise, the
                  files are automatically deleted after installation.































               1-34  Installation Procedure