DIGITAL DATATRIEVE-11 Update Cover Letter AV-PBGXA-TC Software Problem Correction For calculations using variables that were declared for USAGE REAL, the results were improperly scaled. This caused a result to be reported with an improp- erly placed decimal point. The magnitude of the error depended on the scale of the REAL variable and the other factors in the calculation. This problem has been corrected. New AutoInstall Version The version of AutoInstall used with this software is V1.1 instead of V1.0 as documented in the V3.3 Instal- lation Guide. Therefore, when installing AutoInstall on your system, the saveset restoration step should specify AUT101 as the saveset filename rather than AUT100. Installation Prerequisites for RSX-11M and RSX-11M-Plus users If you are a RSX-11M or RSX-11M-Plus user, you cannot simply abort the system startup command file and at- tempt the installation from that point. Similarly, if you have just completed a system generation, certain logical names used by the installation will not have meaning yet. You must log out and then log back in to a privileged account. Before beginning the installation, you should be in your default directory. If you issue a SET DEFAULT command to another directory before starting the in- stallation, Auto-Install may fail. Page 2 Documentation correction On page 12-7 of the User's Guide, the last sentence on the page should indicate a default edit string length of 30 characters instead of 10.